Cyanotic heart defect laboratory findings

Jump to navigation Jump to search

Cyanotic heart defect Microchapters

Home

Patient Information

Overview

Historical Perspective

Classification

Pathophysiology

Causes

Differentiating Cyanotic heart defect from other Diseases

Epidemiology and Demographics

Risk Factors

Screening

Natural History, Complications and Prognosis

Diagnosis

Diagnostic Study of Choice

History and Symptoms

Physical Examination

Laboratory Findings

Electrocardiogram

Chest X Ray

Echocardiography

CT

MRI

Other Imaging Findings

Other Diagnostic Studies

Treatment

Medical Therapy

Interventions

Surgery

Primary Prevention

Secondary Prevention

Cost-Effectiveness of Therapy

Future or Investigational Therapies

Case Studies

Case #1

Cyanotic heart defect laboratory findings On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

Powerpoint slides

Images

American Roentgen Ray Society Images of Cyanotic heart defect laboratory findings

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Cyanotic heart defect laboratory findings

CDC on Cyanotic heart defect laboratory findings

Cyanotic heart defect laboratory findings in the news

Blogs on Cyanotic heart defect laboratory findings

Directions to Hospitals Treating Cyanotic heart defect

Risk calculators and risk factors for Cyanotic heart defect laboratory findings

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor-in-Chief: Keri Shafer, M.D. [2]; Kalsang Dolma, M.B.B.S.[3]

Overview

Laboratory Findings

  • Erythrocytosis
  • The platelet count is usually low
  • Iron deficiency anemia
    • Reduced RBC survival time
    • Increased blood viscosity due to rigid RBCs.
    • Reduces RBCs oxygen carrying capacity
  • Hb > 20gm/dl
  • Increased prothrombin time
  • Increased aPTT
  • Decreased coagulation factors
  • Decreased platelets, abnormal platelet function
  • High uric acid levels (hyperuricemia)
  • Proteinuria
  • Checking oxygen levels in the blood using an arterial blood gas test or by checking it through the skin with a pulse oximeter
  • Complete blood count (CBC)
  • Hyperoxia test: A hyperoxia test is a test that is performed--usually on an infant-- to determine whether the patient's cyanosis is due to lung disease or a problem with blood circulation.[1][2] It is performed by measuring the arterial blood gases of the patient while he breathes room air, then re-measuring the blood gases after the patient has breathed 100% oxygen for 10 minutes.[1][3] If the cause of the cyanosis is due to poor oxygen saturation by the lungs, allowing the patient to breath 100% O2 will augment the lungs' ability to saturate the blood with oxygen, and the partial pressure of oxygen in the arterial blood will rise (usually above 150 mmHg[3]). However, if the lungs are healthy and already fully saturating the blood that is delivered to them, then supplemental oxygen will have no effect, and the partial pressure of oxygen will usually remain below 100mmHg.[3] In this case, the cyanosis is most likely due to blood that moves from the systemic veins to the systemic arteries via a right-to-left shunt without ever going through the lungs.[1]

References

  1. 1.0 1.1 1.2 Fyler, edited by John F. Keane, James E. Lock, Donald C. (2006). Nadas' pediatric cardiology (2nd ed. ed.). Philadelphia [u.a.]: Saunders [u.a.] ISBN 978-1-4160-2390-6.
  2. "When Do Cyanotic Congenital Heart Diseases Present?". Pediatric Education. 2006-01-23. Retrieved 2011-10-26.
  3. 3.0 3.1 3.2 Dr. Ira Shah (2006-02-15). "How To Manage Blue Baby Maha Neocon 2005 pediatric oncall". Pediatriconcall.com. Retrieved 2011-10-26.


Template:WikiDoc Sources