Saphenous vein graft: Difference between revisions

Jump to navigation Jump to search
Line 102: Line 102:
===MR Angiography===
===MR Angiography===


===Postmortem Angiography===


[http://www.peir.net Images courtesy of Professor Peter Anderson DVM PhD and published with permission © PEIR, University of Alabama at Birmingham, Department of Pathology]
<gallery>
Image:Postmortem angiography saphenous vein graft 001.jpg
Image:Postmortem angiography saphenous vein graft 002.jpg
</gallery>


===[[Saphenous Vein Graft Pathology]]===
===[[Saphenous Vein Graft Pathology]]===

Revision as of 17:58, 9 November 2010

Saphenous vein graft
Saphenous vein grafts for coronary arteries

WikiDoc Resources for Saphenous vein graft

Articles

Most recent articles on Saphenous vein graft

Most cited articles on Saphenous vein graft

Review articles on Saphenous vein graft

Articles on Saphenous vein graft in N Eng J Med, Lancet, BMJ

Media

Powerpoint slides on Saphenous vein graft

Images of Saphenous vein graft

Photos of Saphenous vein graft

Podcasts & MP3s on Saphenous vein graft

Videos on Saphenous vein graft

Evidence Based Medicine

Cochrane Collaboration on Saphenous vein graft

Bandolier on Saphenous vein graft

TRIP on Saphenous vein graft

Clinical Trials

Ongoing Trials on Saphenous vein graft at Clinical Trials.gov

Trial results on Saphenous vein graft

Clinical Trials on Saphenous vein graft at Google

Guidelines / Policies / Govt

US National Guidelines Clearinghouse on Saphenous vein graft

NICE Guidance on Saphenous vein graft

NHS PRODIGY Guidance

FDA on Saphenous vein graft

CDC on Saphenous vein graft

Books

Books on Saphenous vein graft

News

Saphenous vein graft in the news

Be alerted to news on Saphenous vein graft

News trends on Saphenous vein graft

Commentary

Blogs on Saphenous vein graft

Definitions

Definitions of Saphenous vein graft

Patient Resources / Community

Patient resources on Saphenous vein graft

Discussion groups on Saphenous vein graft

Patient Handouts on Saphenous vein graft

Directions to Hospitals Treating Saphenous vein graft

Risk calculators and risk factors for Saphenous vein graft

Healthcare Provider Resources

Symptoms of Saphenous vein graft

Causes & Risk Factors for Saphenous vein graft

Diagnostic studies for Saphenous vein graft

Treatment of Saphenous vein graft

Continuing Medical Education (CME)

CME Programs on Saphenous vein graft

International

Saphenous vein graft en Espanol

Saphenous vein graft en Francais

Business

Saphenous vein graft in the Marketplace

Patents on Saphenous vein graft

Experimental / Informatics

List of terms related to Saphenous vein graft

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]

Associate Editors-In-Chief: Cafer Zorkun, M.D., Ph.D. [2], Jason C. Choi, M.D., Xin Yang, M.D.

Please Join in Editing This Page and Apply to be an Editor-In-Chief for this topic: There can be one or more than one Editor-In-Chief. You may also apply to be an Associate Editor-In-Chief of one of the subtopics below. Please mail us [3] to indicate your interest in serving either as an Editor-In-Chief of the entire topic or as an Associate Editor-In-Chief for a subtopic. Please be sure to attach your CV and or biographical sketch.

Overview

Since Rene Favaloro first described it in 1967, coronary artery revascularization with saphenous veins (saphenous vein grafts or SVGs) has become a surgical standard for treatment of coronary artery disease. When a native coronary artery is obstructed, the sutured graft provides a connection between the aorta and the coronary artery beyond the area of obstruction. The procedure is repeated on all the coronary artery segments that are significantly diseased.

The vein is often removed by cardiac surgeons and used for autotransplantation in coronary artery bypass operations, when arterial grafts are not available or many grafts are required, such as in a triple bypass or quadruple bypass.

SVG Anatomy

Saphenous Vein Graft Harvesting

Saphenous Vein Graft Nomenclature

Assessment of Target Vessels for Saphenous Vein Grafting

Pathophysiology of Saphenous Vein Graft Disease

Saphenous Vein Graft Failure and Patency

Definition of Saphenous Vein Graft Failure

Historical Rates of Saphenous Vein Graft Failure

Determinants of Sapheous Vein Graft Patency

Diagnosis and Evaluation of SVG Disease

Symptoms of SVG Occlusion

Chest X-Ray

In a patient who has undergone CABG, a chest X-ray will demonstrate multiple small clips near the heart and coronary arteries. Large circular sternal wires will also be seen. Examples are shown in the images below.

Images courtesy of RadsWiki

Coronary Angiography

Coronary angiography is often used to ascertain the patency and percent stenoses of saphenous vein grafts.

Technique

Most often a Judkin's Right 4 catheter (JR 4) catheter is used to engage the saphenous vein grafts. If this diagnostic catheter has insufficient "reach" to engage the SVG ostium, then an Amplatz catheter can be used. The optimal view to engage the ostium of the SVG varies from operator to operator. The most popular views to engage the ostium are the left anterior oblique 45 degrees view (LAO 45) with no cranial angulation. Some operator will use the right anterior oblique view (RAO) with 45 degrees of angulation and no cranial angulation. It should be noted that the SVGs supplying the left coronary arteries will come off of the left hand side of the screen and those supplying the right coronary artery will come off of the right hand side of the screen.

If an SVG is known from the operative report to exist, but cannot be selectively engaged, then a non-selective aortogram can be performed to aid in identifying the presence and location of patent SVGs. The aortogram is performed with an injection through an angled pigtail catheter with the camera gantry located in the 45 degree left anterior oblique (LAO) position with no cranial angulation.

In order to engage the left internal mammary artery (which is not a saphenous vein graft but is often interrogated during the process of evaluating SVGs), a view with slight cranial, and slight left anterior oblique (LAO) angulation is used. a Judkin's Right 4 catheter (JR 4) catheter is used to engage the ostium of the subclavian artery. With the catheter near the anticipated origin of the subclavian artery, a counterclockwise motion of the catheter is needed to engage the ostium. Once the ostium is engaged, an exchange length 0.038 J tipped wire is then advance into the subclavian artery. A left internal mammary artery (LIMA) catheter is then exchanged to engage the origin of the left internal mammary artery. Again, this engagement is accomplished with counterclockwise motion of the catheter. An injection with the camera in this angulation is a suitable first view of the LIMA, with careful attention in this view paid to the ostium of the LIMA. the next view is often a left anterior oblique (LAO) view with 90 degrees of angulation (LAO 90). This allows for accurate assessment of the LIMA anastomosis to the left anterior descending artery.

Impact of saphenous vein graft radiographic markers on clinical events and angiographic parameters

One technique that has been used to improve the ascertainment of SVG patency and stenosis is the placement of radio-opaque markers. Use of such markers has been associated with shorter cardiac catheterization procedure times and reduced contrast agent volume for postoperative coronary artery bypass graft (CABG) catheterizations. In the large PREVENT 4 study [1][2], approximately half the patients had SVG markers present (51.2% or 910 of 1,778 patients) and half the SVGs (52.3% of SVGs or 2,228 of 4,240). If the patient had a totally occluded SVG (n = 911), visual identification of the occluded SVG was obtained more frequently among those patients who had an SVG marker (90.7% vs 72.1%, p < 0.001). The identification of SVG stenosis which were > 70% did not differ by the use of SVG markers (25.8% with marker vs 24.4% without marker, p = not significant). These findings were also consistent in ostial lesions (n = 942). The use of an SVG marker was not associated with a difference in the long-term risk of death or myocardial infarction (MI). However, it was noted that the rate of perioperative CABG MI was higher among patients who had an SVG marker (10.1% vs 5.5%, odds ratio adjusted 1.86, p = 0.021).

Use of Coronary Angiography of Saphenous Vein Graft Disease as Endpoint in Clinical Trials Evaluating Pharmacotherapy and Device Based Therapies

SVG Patency and SVG Narrowing as a Surrogate Endpoint for Clinical Events

One issue that arises is the suitability of SVG patency, and SVG narrowing as a surrogate endpoint for clinical events.

There are multiple studies demonstrating that SVG closure or failure is associated with clinical events. The association of SVG failure or narrowing with clinical events is complex and should be interpreted in light of the following nuances:

  1. The SVG may close and the native artery may remain open minimizing the symptoms associated with SVG failure. SVG failure may therefore by clinically "silent" or may not be closely associated with "hard endpoints" such as myocardial infarction(MI).
  2. Placement of SVGs has been associated with improved survival over medical therapy particularly in patients with left main disease and three vessel disease. In so far as the mechanism of clinical benefit of SVGs is predicated upon their ongoing patency, this supports the relevance of SVG patency as a surrogate endpoint.
  3. Despite the native artery remaining open after SVG failure, it should be realized that placement of an SVG is associated with more rapid disease progression in the grafted native coronary artery. SVG placement therefore exposes the patient to a risk of more rapid native disease progression. There is a 4 to 6 fold increase in the risk of proximal native vessel occlusion following the placement of an SVG, while there is limited impact upon disease progression downstream from the SVG [3][4][5][6] . While long-term studies demonstrate that as many as 22/23 grafted vessels occlude proximal to the SVG insertion site, the patency beyond the SVG insertion remains better (only 8 of 39 segments failed)[6]. Progression of native disease is more rapid in segments bypassed by and SVG than those bypassed by an arterial conduit (p = 0.001, odds ratio = 2.03)[7]. In summary, if the SVG fails, the patient most often is left with greater progression of the underlying native vessel disease than they would have had had they not had an SVG placed. It is difficult to ascertain the impact of native vessel disease acceleration given the limited duration of follow-up in trials of SVGs. The impact of disease progression may not be apparent for many years and may be underestimated in current trials and analyses.
  4. As a nuance of the above, the impact of SVG failure may depend in part upon when it occurs.
  5. SVG failure not only leads to a potential reduction in antegrade blood flow to the bypassed segment as a result of vessel closure, there is also the potential for embolizaiton from a large occluded conduit into the downstream native circulation. SVGs do not have sidebranches and there is therefore no capacity for alternate run off when occlusion occurs. As a result, SVGs often occlude back to the origin of the SVG. Furthermore, the diameter of SVG often exceeds that of native arteries. As a result of the fact that the SVG occludes back to the ostium and is of a larger volume than a native coronary artery, there is a much larger embolic burden associated with a SVG.
  6. Consistent with the embolic hazard cited above, is the fact that dilation of an SVG failure does not lead to improved clinical outcomes. The fact that opening a closed SVG does not lead to improved outcomes may lead to inappropriate confusion surrounding SVG failure as a relevant clinical outcome. While it may be intuitive that opening an occluded or failed SVG would lead to improved outcomes (consistent with SVG failure being a surrogate), opening the occluded SVG may instead lead to embolizaiton of a large amount of the thrombotic material downstream. Preventing SVG occlusion may be related to improved outcomes, but treating SVG occlusion after it occurs may not be related to improved outcomes. The failure of reopening an occluded SVG to improve outcomes should not detract from the importance and relevance of preventing SVG occlusion in the first place as a valid surrogate endpoint.
  7. The patient is the unit of randomization, but the SVG is the unit most closely related to clinical events.

In summary there are multiple mechanisms whereby SVG patency is related to clinical outcomes.

  1. Closure of the conduit may reduce antegrade blood flow
  2. There may be embolization into the native vessel from the thrombosed SVG conduit, the diameter of which often exceeds the native coronary artery
  3. The SVG may have accelerate native vessel disease which predisposes the patient to adverse outcomes when the vessel occludes

Is the timing of SVG failure relevant? If an anticoagulant (either antiplatelet or antithrombin) is undergoing evaluation of its efficacy in the prevention of thrombotic graft closure, then it is irrelevant if this thrombotic closure is early (in the immediate peri-operative period) or late. It could be hypothesized that the clinical benefit of the anticoagulant agent would be operative during both the early and late follow-up periods.

Potential for Ascertainment Bias

There are several issues that arise with respect to ascertainment bias in the use of coronary angiograms as an endpoint.

  1. The patient may not return for follow-up angiography. Maybe the patient is feeling so well they don't feel compelled to return for repeat angiography (you missed a positive treatment effect), or maybe they are so sick they can't show up (you missed a negative treatment effect). If patients died, traditionally they are counted or imputed as having SVG failure on both a per patient and a per SVG conduit basis. The percent of patients who returned for follow-up angiography was 80% in the PREVENT 4 study [1]
  2. The patient may return for follow-up angiography, but one or more of the SVGs cannot be engaged and selectively injected. As stated above, in the PREVENT 4 study, the use of saphenous vein graft markers improved the odds of finding SVGs in particular occluded SVGs [2]. However, the SVG stenosis 70% or greater at follow-up did not differ by use of markers (25.8% with marker vs 24.4% without marker, p = not significant). In other words, there does not seem to be ascertainment bias whereby failure to find the SVG results in a different outcome (the outcomes in patients with SVG markers with a greater degree of ascertainment of the endpoint were no different).
Per Patient versus Per SVG as the Unit of Analysis

Analyses should be presented on both a per patient basis (the unit of randomization) and a per SVG basis (the unit that is associated with clinical events). Because the behavior of multiple SVGs may be correlated, and this within patient correlation may reduce the estimate of the variance in the population, an adjustment for the within patient correlation must be provided when presenting the results on a per SVG basis[8]. The within patient conocrdance can be adjusted for using a General Linear Model of Intraclass Correlation (GLIMIC) [8].

CT Angiography in the Assessment of Saphenous Vein Graft Disease

MR Angiography

Saphenous Vein Graft Pathology

Treatment

Goals of Treatment

Primarily, the goal should be to detect and treat a SVG stenosis early in the development of ischemia while the SVG is still patent. Although intervention on a chronic total occlusion of a SVG may seem like an effective treatment strategy, it is best avoided. As long as the SVG is not completely occluded, intervention can be performed.

Two additional overall goals of treating SVG stenosis include the resolution of symptomatic ischemia and the prevention/treatment of distal embolization.

Treatment Options

There are many different choices to consider when deciding the most appropriate treatment for SVG stenosis, including PTCA, PCI with bare metal or drug-eluting stents, PCI with covered stents, embolic protection devices, debulking/thrombus removal, and surgical revascularization.

Percutaneous Transluminal Coronary Angioplasty (PTCA)

PTCA has high initial revascularization success rates in the treatment of SVG stenosis. However, it is also associated with high rates of periprocedural complications, including acute vessel closure secondary to dissection and in-situ thrombosis. Additional complications include distal embolization and no reflow, which can lead to periprocedural infarction.

In modern interventional cardiology, PTCA is not often used as the sole means of treatment for SVG stenosis. Instead, stenting has become the cornerstone of treatment, while the use of PTCA has been limited to pre-dilation and post-dilation.

PCI with Bare Metal Stents (BMS) or Drug-eluting Stents (DES)

Most current vein graft treatment strategies utilize PCI with stents (BMS or DES), since stenting is a superior treatment when compared to PTCA alone. As demonstrated in the SAVED (Saphenous Vein De Novo) Trial[9], the use of stents is associated with higher revascularization success rates, decreased restenosis rates, and improved clinical outcomes when compared to PTCA. Generally, DES are preferred over BMS, since DES are associated with reduced rates of restenosis and target vessel revascularization.

Despite their higher success rates, stents are not immune to restenosis. Predictors for restenosis include long stent length, multiple stents, overlapping stents, smaller vessel size, diabetes mellitus, and stenosis at the coronary or aortic anastomosis.

PCI with Covered Stents

Theoretically, stents covered with a polymer membrane would have higher success rates than standard BMS and DES. One would expect covered stents to effectively trap friable atheroma and isolate the graft lumen from the diseased wall, thereby reducing incidence of restenosis, distal embolization, and no reflow in comparison to traditional stents. However, the RECOVERS (The Randomized Evaluation of polytetrafluoroethylene COVERed stent in Saphenous vein grafts)[10] and STING (STents IN Grafts)[11] trials did not show any advantage in using covered stents when compared to bare metal stents for SVG lesions.

Embolic Protection Devices

During PCI of SVGs, atheroembolic debris can be liberated. This debris contains vasoactive substances that can contribute to no reflow, which can in turn considerably increase the risk of major adverse clinical events (MACE)[12]. Fortunately, embolic protection devices help capture this debris and improve outcomes in PCI for SVG stenosis. Therefore, it is recommended that these devices should be utilized in the intervention of most SVG lesions.

Currently, the FDA has approved five embolic protection devices in the United States. Specifically, these devices include one distal occlusion device, three filters, and one proximal occlusion device.

The FDA-approved distal occlusion device is called the PercuSurge Guardwire®, which involves inflating a balloon distal to the stenosis to occlude flow, thereby trapping the debris and vasoactive substances and preventing them from flowing downstream. Due to its small size, it requires little landing zone to deploy. The SAFER (Saphenous vein graft Angioplasty Free of Emboli Randomized) trial[13] showed that when compared to conventional guidewires, balloon occlusion devices (PercuSurge Guardwire®) reduced the rates of infarction and no-reflow after intervention. Despite these advantages, the PercuSurge Guardwire® may not be the best option for all, as some patients may not tolerate the necessary 3-5 minutes of ischemic time associated with this device. Additionally, it is known to cause both hemodynamic and arrhythmic complications.

Filter devices allow continual distal perfusion while macroscopic emboli are trapped in the filter. The FIRE (FilterWire EX During Transluminal Intervention of Saphenous Vein Grafts) trial[14][15] showed that FilterWire may be preferred over PercuSurge Guardwire® due to improved clinical outcomes. While they may reduce ischemic time, filter devices are associated with their own set of potential complications. They are more difficult to deliver than balloon occlusion devices, so their own delivery may lead to distal embolization, and they may not trap microscopic mediators of no reflow. Additionally, they require a significant landing zone distal to the lesion for the filter placement, which can be problematic for certain distal lesions that do not have enough room. There have also been case reports of filter entrapment in the graft after the completion of the PCI.

The FDA-approved proximal occlusion device is called the Proxis® device. Some advantages of this decide are that its deployment does not require crossing the stenosis, it provides superior support that is helpful where balloon or stent delivery is difficult, and it provides protected crossing of the lesion, if required. However, as shown by the PROXIMAL (Proximal Protection During Saphenous Vein Graft Intervention Using the Proxis Embolic Protection System) trial[16], in terms of overall outcomes, there is no significant difference in death, MI, or target vessel revascularization (TVR) between distal and proximal embolic protection devices.

Debulking/Thrombus Removal

Data has not demonstrated a durable clinical benefit associated with debulking/thrombus removal. However, there are certain situations in which debulking techniques may be useful when treating saphenous vein grafts. For instance, severely calcified and stenotic lesions can make regular stent insertion especially difficult. When SVG lesions are too calcified to be crossed by a balloon or adequately dilated prior to stent placement, debulking and thrombus removal can change the compliance of the vessel wall. In addition, this technique is also useful if a lesion is at the aorto-ostial junction. Adjunctive stenting leads to better short and long term results.

There are several debulking/thrombus removal techniques, including directional coronary atherectomy, transluminal extraction catheter thrombectomy, rotational atherectomy, and laser atherectomy.

  • Directional coronary atherectomy (DCA) uses a circular cutting blade that excises atheroma into a chamber for removal. It is useful for aorto-ostial lesions and focal lesions in large vessels. However, due to its bulky nature, it is generally not used in vessels with angulation, tortuosity, or heavy calcification. CAVEAT II (Coronary Angioplasty Versus Excisional Atherectomy Trial)[17] examined how PTCA and DCA compared in the treatment of patients with coronary artery bypass graft stenoses. This study demonstrated that DCA was associated with higher initial angiographic success rates and larger acute luminal dimensions in comparison to PTCA. However, despite these successes, DCA also displayed an increased rate of non-Q wave myocardial infusion and distal embolization than PTCA. Furthermore, both techniques displayed similar restenosis rates.
Additionally, a retrospective study compared DCA vs. PTCA alone vs. PCI with stenting in SVG lesions. It showed no differences in mortality, angina, infarction, or repeat revascularization among the different methods. However, this study displayed increased angiographic complications with DCA use.
  • Transluminal extraction catheter (TEC) thrombectomy is designed to remove thrombus from SVGs prior to stenting. It operates through the use of cutting blades with a rotating catheter and an external suction device. However, because the TEC Best trial showed no benefit of TEC prior to the stenting of SVGs, this technique has fallen out of favor. Furthermore, TEC is also associated with a significant incidence of distal embolization and no reflow.
  • Laser atherectomy uses monochromatic light energy to disrupt plaques. Despite this approach's innovation, there is no evidence that this strategy improves outcomes in lesions, and it has been complicated by high rates of dissection and perforation.

Surgical Revascularization

Given increased perioperative mortality, surgical revascularization is not an optimal treatment strategy, as many patients with graft disease are poor surgical candidates. However, surgery may be required in patients with multi-vessel disease and when PCI fails.

Additionally, reoperation is not strongly encouraged, as it does not provide the same level of revascularization and resolution of angina as the initial procedure. Furthermore, a LIMA may be jeopardized in a reoperation.

Making a Selection

At the earliest signs of recurrent ischemia, it is important to strongly consider the possibility of a patent but stenosed SVG, so that the graft lesion can be treated before the graft becomes completely occluded. Prompt treatment is essential, since a graft is lost once it becomes completely occluded.

Regardless of treatment choice, all patients should be given statins and aspirin (begun immediately following CABG), which are effective in the secondary prevention of SVG stenosis.

For most SVG lesions, PCI with stenting appears to be the therapy of choice. DES are associated with a decreased restenosis rate over BMS, and should be used preferentially if the patient is able to tolerate dual platelet therapy for a minimum of a year. Furthermore, embolic protection devices should be strongly considered for all SVG lesions, especially those with high risks for distal embolization.

In cases in which stent delivery and expansion may be difficult due to heavily calcified and stenotic lesions, atherectomy devices, used with stenting, may be considered. Furthermore, these devices can be useful in lesions that are aorto-ostial.

Zoghbi et al. conducted a study to investigate the role of pretreatment with nitroprusside before SVG intervention[18]. They studied sixty-four consecutive patients with normal preprocedural cardiac enzymes that underwent SVG PCI, without the use of embolic protection devices. They found that pretreatment with nitroprusside results in a lower magnitude and frequency of post-procedural cardiac enzyme elevation. Thus, it is important to consider nitroprusside use.

Finally, while GP IIb/IIIa inhibitors are frequently used in the setting of SVG intervention, their benefit has not been fully evaluated in randomized trials of this lesion subset.


Saphenous Vein Graft Intervention Complications

Clinical Trials

References

  1. 1.0 1.1 Alexander JH, Hafley G, Harrington RA, Peterson ED, Ferguson TB, Lorenz TJ, Goyal A, Gibson M, Mack MJ, Gennevois D, Califf RM, Kouchoukos NT (2005). "Efficacy and safety of edifoligide, an E2F transcription factor decoy, for prevention of vein graft failure following coronary artery bypass graft surgery: PREVENT IV: a randomized controlled trial". JAMA : the Journal of the American Medical Association. 294 (19): 2446–54. doi:10.1001/jama.294.19.2446. PMID 16287955. Unknown parameter |month= ignored (help); |access-date= requires |url= (help)
  2. 2.0 2.1 Olenchock SA, Karmpaliotis D, Gibson WJ, Murphy SA, Southard MC, Ciaglo L, Buros J, Mack MJ, Alexander JH, Harrington RA, Califf RM, Kouchoukos NT, Ferguson TB, Gibson CM (2008). "Impact of saphenous vein graft radiographic markers on clinical events and angiographic parameters". The Annals of Thoracic Surgery. 85 (2): 520–4. doi:10.1016/j.athoracsur.2007.10.061. PMID 18222256. Retrieved 2010-10-31. Unknown parameter |month= ignored (help)
  3. Borowski A, Vchivkov I, Ghodsizad A, Gams E (2008). "Coronary artery disease progression in patients who need repeat surgical revascularisation: the surgeon's point of view". Journal of Cardiovascular Medicine (Hagerstown, Md.). 9 (1): 85–8. doi:10.2459/JCM.0b013e328011439e. PMID 18268427. Retrieved 2010-10-31. Unknown parameter |month= ignored (help)
  4. Hamada Y, Kawachi K, Yamamoto T, Nakata T, Kashu Y, Watanabe Y, Sato M (2001). "Effect of coronary artery bypass grafting on native coronary artery stenosis. Comparison of internal thoracic artery and saphenous vein grafts". The Journal of Cardiovascular Surgery. 42 (2): 159–64. PMID 11292927. Unknown parameter |month= ignored (help); |access-date= requires |url= (help)
  5. Rupprecht HJ, Hamm C, Ischinger T, Dietz U, Reimers J, Meyer J (1996). "Angiographic follow-up results of a randomized study on angioplasty versus bypass surgery (GABI trial). GABI Study Group". European Heart Journal. 17 (8): 1192–8. PMID 8869860. Retrieved 2010-10-31. Unknown parameter |month= ignored (help)
  6. 6.0 6.1 Guthaner DF, Robert EW, Alderman EL, Wexler L (1979). "Long-term serial angiographic studies after coronary artery bypass surgery". Circulation. 60 (2): 250–9. PMID 312703. Retrieved 2010-10-31. Unknown parameter |month= ignored (help)
  7. Manninen HI, Jaakkola P, Suhonen M, Rehnberg S, Vuorenniemi R, Matsi PJ (1998). "Angiographic predictors of graft patency and disease progression after coronary artery bypass grafting with arterial and venous grafts". The Annals of Thoracic Surgery. 66 (4): 1289–94. PMID 9800822. Retrieved 2010-10-31. Unknown parameter |month= ignored (help)
  8. 8.0 8.1 Gibson CM, Kuntz RE, Nobuyoshi M, Rosner B, Baim DS (1993). "Lesion-to-lesion independence of restenosis after treatment by conventional angioplasty, stenting, or directional atherectomy. Validation of lesion-based restenosis analysis". Circulation. 87 (4): 1123–9. PMID 8462141. Retrieved 2010-10-31. Unknown parameter |month= ignored (help)
  9. Savage MP, Douglas JS, Fischman DL; et al. (1997). "Stent placement compared with balloon angioplasty for obstructed coronary bypass grafts. Saphenous Vein De Novo Trial Investigators". N. Engl. J. Med. 337 (11): 740–7. PMID 9287229. Unknown parameter |month= ignored (help)
  10. Stankovic G, Colombo A, Presbitero P; et al. (2003). "Randomized evaluation of polytetrafluoroethylene-covered stent in saphenous vein grafts: the Randomized Evaluation of polytetrafluoroethylene COVERed stent in Saphenous vein grafts (RECOVERS) Trial". Circulation. 108 (1): 37–42. doi:10.1161/01.CIR.0000079106.71097.1C. PMID 12821546. Unknown parameter |month= ignored (help)
  11. Schächinger V, Hamm CW, Münzel T; et al. (2003). "A randomized trial of polytetrafluoroethylene-membrane-covered stents compared with conventional stents in aortocoronary saphenous vein grafts". J. Am. Coll. Cardiol. 42 (8): 1360–9. PMID 14563575. Unknown parameter |month= ignored (help)
  12. Salloum J, Tharpe C, Vaughan D, Zhao DX (2005). "Release and elimination of soluble vasoactive factors during percutaneous coronary intervention of saphenous vein grafts: analysis using the PercuSurge GuardWire distal protection device". J Invasive Cardiol. 17 (11): 575–9. PMID 16264199. Unknown parameter |month= ignored (help)
  13. Baim DS, Wahr D, George B; et al. (2002). "Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts". Circulation. 105 (11): 1285–90. PMID 11901037. Unknown parameter |month= ignored (help)
  14. Stone GW, Rogers C, Hermiller J; et al. (2003). "Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts". Circulation. 108 (5): 548–53. doi:10.1161/01.CIR.0000080894.51311.0A. PMID 12874191. Unknown parameter |month= ignored (help)
  15. Halkin A, Masud AZ, Rogers C; et al. (2006). "Six-month outcomes after percutaneous intervention for lesions in aortocoronary saphenous vein grafts using distal protection devices: results from the FIRE trial". Am. Heart J. 151 (4): 915.e1–7. doi:10.1016/j.ahj.2005.09.018. PMID 16569562. Unknown parameter |month= ignored (help)
  16. Mauri L, Cox D, Hermiller J; et al. (2007). "The PROXIMAL trial: proximal protection during saphenous vein graft intervention using the Proxis Embolic Protection System: a randomized, prospective, multicenter clinical trial". J. Am. Coll. Cardiol. 50 (15): 1442–9. doi:10.1016/j.jacc.2007.06.039. PMID 17919563. Unknown parameter |month= ignored (help)
  17. Holmes DR, Topol EJ, Califf RM; et al. (1995). "A multicenter, randomized trial of coronary angioplasty versus directional atherectomy for patients with saphenous vein bypass graft lesions. CAVEAT-II Investigators". Circulation. 91 (7): 1966–74. PMID 7895354. Unknown parameter |month= ignored (help)
  18. Zoghbi GJ, Goyal M, Hage F; et al. (2009). "Pretreatment with nitroprusside for microcirculatory protection in saphenous vein graft interventions". J Invasive Cardiol. 21 (2): 34–9. PMID 19182287. Unknown parameter |month= ignored (help)

Additional Resources

  • S. A. Hassantash, B. Bikdeli, S. Kalantarian, M. Sadeghian, and H. Afshar Pathophysiology of Aortocoronary Saphenous Vein Bypass Graft Disease Asian Cardiovasc Thorac Ann, August 1, 2008; 16(4): 331 - 336.
  • A. Coolong, D. S. Baim, R. E. Kuntz, A. J. O'Malley, S. Marulkar, D. E. Cutlip, J. J. Popma, and L. Mauri. Saphenous Vein Graft Stenting and Major Adverse Cardiac Events: A Predictive Model Derived From a Pooled Analysis of 3958 Patients. Circulation, February 12, 2008; 117(6): 790 - 797.
  • R. F. Padera Jr. and F. J. Schoen. Pathology of Cardiac Surgery Card. Surg. Adult, January 1, 2008; 3(2008): 111 - 178.
  • E. Gongora and T. M. Sundt III. Myocardial Revascularization with Cardiopulmonary Bypass. Card. Surg. Adult, January 1, 2008; 3(2008): 599 - 632.
  • P. Widimsky, Z. Straka, P. Stros, K. Jirasek, J. Dvorak, J. Votava, L. Lisa, T. Budesinsky, M. Kolesar, T. Vanek, et al. One-Year Coronary Bypass Graft Patency: A Randomized Comparison Between Off-Pump and On-Pump Surgery Angiographic Results of the PRAGUE-4 Trial Circulation, November 30, 2004; 110 (22): 3418 - 3423.
  • M. A. Hlatky, D. B. Boothroyd, K. A. Melsop, M. M. Brooks, D. B. Mark, B. Pitt, G. S. Reeder, W. J. Rogers, T. J. Ryan, P. L. Whitlow, et al. Medical Costs and Quality of Life 10 to 12 Years After Randomization to Angioplasty or Bypass Surgery for Multivessel Coronary Artery Disease Circulation, October 5, 2004; 110 (14): 1960 - 1966.
  • J. G. Lobo Filho, M. C. d. A. Leitao, and A. J. d. V. Forte Studying the lumen in composite Y internal thoracic artery-saphenous vein grafts J. Thorac. Cardiovasc. Surg., September 1, 2004; 128(3): 490 - 491.
  • E. McGregor, L. Kempster, R. Wait, M. Gosling, M. J. Dunn, and J. T. Powell. F-actin Capping (CapZ) and Other Contractile Saphenous Vein Smooth Muscle Proteins Are Altered by Hemodynamic Stress: a proteomic approach Mol. Cell. Proteomics, February 1, 2004; 3(2): 115 - 124.
  • M. Endo, Y. Tomizawa, and H. Nishida Bilateral Versus Unilateral Internal Mammary Revascularization in Patients with Diabetes Circulation, September 16, 2003; 108(11): 1343 - 1349.
  • T. D. Rea, M. Crouthamel, M. S. Eisenberg, L. J. Becker, and A. R. Lima. Temporal Patterns in Long-Term Survival After Resuscitation From Out-of-Hospital Cardiac Arrest Circulation, September 9, 2003; 108(10): 1196 - 1201.
  • M. Hilker, T. Langin, U. Hake, F.-X. Schmid, W. Kuroczynski, H.-A. Lehr, H. Oelert, and M. Buerke Gene expression profiling of human stenotic aorto-coronary bypass grafts by cDNA array analysis Eur. J. Cardiothorac. Surg., April 1, 2003; 23(4): 620 - 625.
  • J. L. Sperry, C. B. Deming, C. Bian, P. L. Walinsky, D. A. Kass, F. D. Kolodgie, R. Virmani, A. Y. Kim, and J. J. Rade Wall Tension Is a Potent Negative Regulator of In Vivo Thrombomodulin Expression Circ. Res., January 10, 2003; 92(1): 41 - 47.
  • F. J. Schoen and R. F. Padera Jr. Cardiac Surgical Pathology Card. Surg. Adult, January 1, 2003; 2(2003): 119 - 185.
  • A. Y. Kim, P. L. Walinsky, F. D. Kolodgie, C. Bian, J. L. Sperry, C. B. Deming, E. A. Peck, J. G. Shake, G. B. Ang, R. H. Sohn, et al. Early Loss of Thrombomodulin Expression Impairs Vein Graft Thromboresistance: Implications for Vein Graft Failure Circ. Res., February 8, 2002; 90(2): 205 - 212.
  • K. B. Kim, C. Lim, C. Lee, I.-H. Chae, B.-H. Oh, M.-M. Lee, and Y.-B. Park Off-pump coronary artery bypass may decrease the patency of saphenous vein grafts Ann. Thorac. Surg., September 1, 2001; 72(3): S1033 - 1037.
  • Z. Yang, T. Kozai, B. van de Loo, H. Viswambharan, M. Lachat, M. I. Turina, T. Malinski, and T. F. Luscher. HMG-CoA reductase inhibition improves endothelial cell function and inhibits smooth muscle cell proliferation in human saphenous veins J. Am. Coll. Cardiol., November 1, 2000; 36(5): 1691 - 1697.
  • H. Hirose, A. Amano, S. Yoshida, A. Takahashi, N. Nagano, and T. Kohmoto Coronary Artery Bypass Grafting in the Elderly Chest, May 1, 2000; 117(5): 1262 - 1270.
  • D. R. Holmes Jr and P. B. Berger. Percutaneous Revascularization of Occluded Vein Grafts : Is It Still a Temptation to Be Resisted? Circulation, January 12, 1999; 99(1): 8 - 11.
  • Y. K. Wong, M. Thomas, V. Tsang, P. J. Gallagher, and M. E. Ward. The prevalence of Chlamydia pneumoniae in atherosclerotic and nonatherosclerotic blood vessels of patients attending for redo and first time coronary artery bypass graft surgery. J. Am. Coll. Cardiol., January 1, 1999; 33(1): 152 - 156.
  • F. D. Loop Coronary artery surgery: the end of the beginning Eur. J. Cardiothorac. Surg., December 1, 1998; 14(6): 554 - 571.
  • Z. G. Zhu, H.-H. Li, and B.-R. Zhang. Expression of Endothelin-1 and Constitutional Nitric Oxide Synthase Messenger RNA in Saphenous Vein Endothelial Cells Exposed to Arterial Flow Shear Stress Ann. Thorac. Surg., November 1, 1997; 64(5): 1333 - 1338.
  • A. Y. Kim, P. L. Walinsky, F. D. Kolodgie, C. Bian, J. L. Sperry, C. B. Deming, E. A. Peck, J. G. Shake, G. B. Ang, R. H. Sohn, et al. Early Loss of Thrombomodulin Expression Impairs Vein Graft Thromboresistance: Implications for Vein Graft Failure. Circ. Res., February 8, 2002; 90(2): 205 - 212.

See Also

External Links


Template:SIB

Template:WH Template:WS