Prosthetic valve regurgitation: Difference between revisions

Jump to navigation Jump to search
 
Line 3: Line 3:
perforation.
perforation.
*Even in asymptomatic patients with severe bioprosthetic regurgitation, valve replacement is reasonable because of the risk of sudden
*Even in asymptomatic patients with severe bioprosthetic regurgitation, valve replacement is reasonable because of the risk of sudden
clinical deterioration if further leaflet tearing occurs.241 The increased risk of a repeat operation must always be taken into consideration.
clinical deterioration if further leaflet tearing occurs. The increased risk of a repeat operation must always be taken into consideration.
*The type of valve prosthesis and method of replacement selected for a patient undergoing reoperation depend on the same factors as those for patients
undergoing a first valve replacement.

Latest revision as of 14:03, 21 January 2020

Prosthetic valve regurgitation

  • Bioprosthetic valve degeneration can result in regurgitation due to leaflet calcification and noncoaptation or leaflet degeneration with a tear or

perforation.

  • Even in asymptomatic patients with severe bioprosthetic regurgitation, valve replacement is reasonable because of the risk of sudden

clinical deterioration if further leaflet tearing occurs. The increased risk of a repeat operation must always be taken into consideration.

  • The type of valve prosthesis and method of replacement selected for a patient undergoing reoperation depend on the same factors as those for patients

undergoing a first valve replacement.