== Methods of Pacing ==
Cardiac pacemakers consist of two parts: a '''pulse generator''' or simply generator which is the source of electric pulse, and a variable number of '''leads''' that convey the electric signal from the generator to the [[Myocardium|myocardium]]. Newer leadless pacemakers have been introduced reducing the risk of complications. There is no formal classification system for the pacemaker. Based upon their duration of use they can be divided into '''temporary pacing''' or emergency use pacing and '''permanent pacing'''.


=== Temporary pacing ===
Temporary pacing is indicated if permanent pacing is not instantly available, not required, or contraindicated. Different types of temporary pacing techniques (based upon the method used to consign the leads to the heart chambers) include transvenous pacing, transcutaneous pacing, epicardial pacing, transesophageal atrial pacing<ref name="pmid16943920">{{cite journal |vauthors=Verbeet T, Castro J, Decoodt P |title=Transesophageal pacing: a versatile diagnostic and therapeutic tool |journal=Indian Pacing Electrophysiol J |volume=3 |issue=4 |pages=202–9 |date=October 2003 |pmid=16943920 |pmc=1502053 |doi= |url=}}</ref>, transthoracic mechanical pacing, transthoracic pacing<ref name="pmid6383140">{{cite journal |vauthors=Hedges JR, Syverud SA, Dalsey WC |title=Developments in transcutaneous and transthoracic pacing during bradyasystolic arrest |journal=Ann Emerg Med |volume=13 |issue=9 Pt 2 |pages=822–7 |date=September 1984 |pmid=6383140 |doi=10.1016/s0196-0644(84)80450-3 |url=}}</ref> and transmediastinal pacing.
<br />
{| class="wikitable"
! colspan=4 style="background: #4479BA; color: #FFFFFF; " align="center"|Types of temporary pacing
|-
!style="background: #4479BA; color: #FFFFFF; " align="center" |Type
!style="background: #4479BA; color: #FFFFFF; " align="center" |Procedure
!style="background: #4479BA; color: #FFFFFF; " align="center" |Use
!style="background: #4479BA; color: #FFFFFF; " align="center" |Limitation/ Complication
|-
|style="background: #DCDCDC; |'''Transvenous pacing'''
|{{main|Transvenous pacing}} Under sterile conditions, a pacemaker wire guided by [[Fluoroscopy|fluoroscopy]] or [[Echocardiography|echocardiography]] is placed into a vein. Internal jugular vein or subclavian vein are the most common access sites. It is then passed into either the right atrium or right ventricle. The pacing wire is then connected to an external pacemaker outside the body and appropriate mode is selected.
|Alternative to transcutaneous pacing and bridge to permanent pacing.
|Infection, thrombosis, pneumothorax, hemothorax, pericardial tamponade<ref name="MetkusSchulman2019">{{cite journal|last1=Metkus|first1=Thomas S.|last2=Schulman|first2=Steven P.|last3=Marine|first3=Joseph E.|last4=Eid|first4=Shaker M.|title=Complications and Outcomes of Temporary Transvenous Pacing|journal=Chest|volume=155|issue=4|year=2019|pages=749–757|issn=00123692|doi=10.1016/j.chest.2018.11.026}}</ref>
|-
|style="background: #DCDCDC; |'''Transcutaneous pacing'''/ External pacing
|The procedure described in:{{main|Transcutaneous pacing}} External pacing should not be relied upon for an extended period of time.
|1.Emergencies as hemodynamically significant [[bradycardia]]s or asystole <br>2. bridge to transvenous pacing
|discomfort to the patient, risk of burns to skin, musculoskeletal stimulation
|-
|style="background: #DCDCDC; |'''[[Epicardial]] Pacing'''
|Temporary epicardial pacing is used during open-heart surgery should the surgical procedure create [[Atrioventricular block|atrioventricular block]]. The electrodes are placed in contact with the [[Epicardium|outer wall]] of the ventricle to maintain satisfactory cardiac output until a temporary transvenous electrode has been inserted.
|
|
|-
|style="background: #DCDCDC; |'''Transesophageal pacing'''
|Due to the close proximity to atrium, transesophageal pacing is used.
|
|
|-
|style="background: #DCDCDC; |'''Transthoracic pacing'''
|
|
|
|-
|style="background: #DCDCDC; |'''Transthoracic mechanical pacing'''/ Percussive pacing
|An old procedure involves the use of the closed fist, usually on the left lower edge of the sternum over the right ventricle. According to the British Journal of Anesthesia Striking from a distance of 20 - 30 cm to raise the ventricular pressure 10 - 15mmHg will induce electrical activity and hence ventricular beat.<ref>(Cite_Journal)Percussion pacing in a three-year-old girl with complete heart block during cardiac catheterization. C Eich, A Bleckmann and T. Paul, retrieved from http://bja.oxfordjournals.org/cgi/content/full/95/4/465</ref>
|only as a life-saving mean until an electrical pacemaker is available
|
|-
|style="background: #DCDCDC; |'''Transmediastinal pacing'''
|
|
|
|}
=== Permanent Pacing ===
[[Image:Fluoroscopy pacemaker leads right atrium ventricle.png|thumb|left|Right atrial and right ventricular leads as visualized under X-ray during a pacemaker implant procedure. The atrial lead is the curved one making a U shape in the upper left part of the figure.]]
Permanent pacing with an implantable pacemaker involves the transvenous placement of one or more pacing electrodes within a chamber, or chambers, of the heart. The procedure is performed by the incision of a suitable vein into which the electrode lead is inserted and passed along the vein, through the valve of the heart, until positioned in the chamber. The procedure is facilitated by [[fluoroscopy]] which enables the physician or cardiologist to view the passage of the electrode lead. After satisfactory lodgment of the electrode is confirmed the opposite end of the electrode lead is connected to the pacemaker generator.
The pacemaker generator is a hermetically sealed device containing a power source, usually a lithium battery, a sensing amplifier which processes the electrical manifestation of naturally occurring heartbeats as sensed by the heart electrodes, the computer logic for the pacemaker and the output circuitry which delivers the pacing impulse to the electrodes.
Most commonly, the generator is placed below the subcutaneous fat of the chest wall, above the muscles and bones of the chest. However, the placement may vary on a case by case basis.
The outer casing of pacemakers is so designed that it will rarely be rejected by the body's [[immune system]]. It is usually made of [[titanium]], which is inert in the body.