Varicose veins other diagnostic studies: Difference between revisions

Jump to navigation Jump to search
No edit summary
No edit summary
Line 3: Line 3:
{{CMG}}
{{CMG}}


The convenience of Duplex Ultrasonography for Varicose veins has driven down the demand and importance of Physiologic testing. Some physiologic tests for varicose veins are Maximal venous outflow(MVO), Venous refill time(VRT), and Calf Muscle pump Ejection fraction(MPEF)<ref>https://emedicine.medscape.com/</ref>.
The convenience of [[Ultrasonography|Duplex Ultrasonography]] for Varicose veins has driven down the demand and importance of Physiologic testing. Varicose veins usually occur in the superficial veins due to failure of venous valve system( which protects the superficial veins from high pressure of the deep vein system). Some physiologic tests for varicose veins are [[Maximal venous outflow]](MVO), Venous refill time(VRT), and Calf Muscle pump Ejection fraction(MPEF)<ref>https://emedicine.medscape.com/</ref>.


*Venous Refill Time(VRT): It is the time taken by the blood to completely fill up the leg after it has been thoroughly emptied by the calf muscle pump. In a limb with a normal venous valve system, it is filled by the arterial system alone and takes up to 2 minutes. However, if the venous valves are incompetent, the blood leaks back and the filling time is much shorter. It is 40 seconds to 120 seconds long in people with mild/asymptomatic cases. In patients with significant valvular incompetence, it can be as short as 20-40 seconds.
*Venous Refill Time(VRT): It is the time taken by the blood to completely fill up the [[Leg (anatomy)|leg]] after it has been thoroughly emptied by the [[calf muscle]] pump. In a limb with a normal venous valve system, it is filled by the arterial system alone and takes up to 2 minutes. However, if the venous valves are incompetent, the blood leaks back and the filling time is much shorter. It is 40 seconds to 120 seconds long in people with mild/asymptomatic cases. In patients with significant valvular incompetence, it can be as short as 20-40 seconds.


* Maximal Venous Outflow(MVO): In this test, we measure the maximum venous blood flow immediately after releasing a tied up tourniquet on the limb that is maximally congested. The downside of this test is that it is not very sensitive and works only when there is significant venous obstruction. Hence, even a normal test result wouldn't rule out partial obstruction or venous incompetency state.  
* Maximal Venous Outflow(MVO): In this test, we measure the maximum venous blood flow immediately after releasing a tied up tourniquet on the limb that is maximally congested. The downside of this test is that it is not very sensitive and works only when there is significant venous obstruction. Hence, even a normal test result would not rule out partial obstruction or venous incompetence.


*Calf Muscle Pump Ejection Fraction(MPEF): The patient is told to do 10-20 dorsiflexions of the ankle joint of the limb undergoing testing while some physical parameter is used to track calf muscle blood volume. Normally, this would completely empty the calf venous capacitance circuit. However, in patients with severe venous incompetence, this would barely make any difference.
*Calf Muscle Pump Ejection Fraction(MPEF): The patient is told to do 10-20 dorsiflexions of the ankle joint of the limb undergoing testing while some physical parameter is used to track [[calf muscle]] blood volume. Normally, this would completely empty the calf venous capacitance circuit. However, in patients with severe [[venous incompetence]], this would barely make any difference.
   
   
==References==
==References==

Revision as of 07:14, 7 August 2020

Varicose veins Microchapters

Home

Patient Information

Overview

Historical Perspective

Classification

Pathophysiology

Causes

Differentiating Varicose veins from other Diseases

Epidemiology and Demographics

Risk Factors

Screening

Natural History, Complications and Prognosis

Diagnosis

History and Symptoms

Physical Examination

Laboratory Findings

CT

MRI

Ultrasound

Other Imaging Findings

Other Diagnostic Studies

Treatment

Medical Therapy

Surgery

Primary Prevention

Secondary Prevention

Cost-Effectiveness of Therapy

Future or Investigational Therapies

Case Studies

Case #1

Varicose veins other diagnostic studies On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

Powerpoint slides

Images

American Roentgen Ray Society Images of Varicose veins other diagnostic studies

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

Guidance

FDA on Varicose veins other diagnostic studies

on Varicose veins other diagnostic studies

Varicose veins other diagnostic studies in the news

Blogs on Varicose veins other diagnostic studies

Directions to Hospitals Treating Varicose veins

Risk calculators and risk factors for Varicose veins other diagnostic studies

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]

The convenience of Duplex Ultrasonography for Varicose veins has driven down the demand and importance of Physiologic testing. Varicose veins usually occur in the superficial veins due to failure of venous valve system( which protects the superficial veins from high pressure of the deep vein system). Some physiologic tests for varicose veins are Maximal venous outflow(MVO), Venous refill time(VRT), and Calf Muscle pump Ejection fraction(MPEF)[1].

  • Venous Refill Time(VRT): It is the time taken by the blood to completely fill up the leg after it has been thoroughly emptied by the calf muscle pump. In a limb with a normal venous valve system, it is filled by the arterial system alone and takes up to 2 minutes. However, if the venous valves are incompetent, the blood leaks back and the filling time is much shorter. It is 40 seconds to 120 seconds long in people with mild/asymptomatic cases. In patients with significant valvular incompetence, it can be as short as 20-40 seconds.
  • Maximal Venous Outflow(MVO): In this test, we measure the maximum venous blood flow immediately after releasing a tied up tourniquet on the limb that is maximally congested. The downside of this test is that it is not very sensitive and works only when there is significant venous obstruction. Hence, even a normal test result would not rule out partial obstruction or venous incompetence.
  • Calf Muscle Pump Ejection Fraction(MPEF): The patient is told to do 10-20 dorsiflexions of the ankle joint of the limb undergoing testing while some physical parameter is used to track calf muscle blood volume. Normally, this would completely empty the calf venous capacitance circuit. However, in patients with severe venous incompetence, this would barely make any difference.

References