You don't need to be Editor-In-Chief to add or edit content to WikiDoc. You can begin to add to or edit text on this WikiDoc page by clicking on the edit button at the top of this page. Next enter or edit the information that you would like to appear here. Once you are done editing, scroll down and click the Save page button at the bottom of the page.
In semiconductor manufacturing plasma ashing is the process of removing the photoresist from an etched wafer. Using a plasma source, a monatomic reactive species is generated. Oxygen or fluorine are the most common reactive species. The reactive species combines with the photoresist to form ash which is removed with a vacuum pump.
Typically, monatomic (single atom) oxygen plasma is created by exposing oxygen gas (O2) to ionizing radiation. At the same time, many free radicals are formed which could damage the wafer. Newer, smaller circuitry is increasingly susceptible to these particles. Originally, plasma was generated in the process chamber, but as the need to get rid of free radicals has increased, many machines now use a downstream plasma configuration, where plasma is formed remotely and channeled to the wafer. This allows electrically charged particles time to recombine before they reach the wafer surface, and prevents damage to the wafer surface.
Monatomic oxygen is electrically neutral and although it does recombine during the channeling, it does so at a slower rate than the positively or negatively charged free radicals, which attract one another. Effectively, this means that when all of the free radicals have recombined, there is still a portion of the active species available for process. Because a large portion of the active specie is lost to recombination, process times may take longer. To some extent, these longer process times can be mitigated by increasing the temperature of the reaction area.
de:PlasmaƤtzenAcknowledgement and Attribution Regarding Sources of Content
Some of the initial content on this page may be incorporated in part from copyleft sources in the public domain including wikis such as Wikipedia and AskDrWiki. Drug information for patients came from the The National Library of Medicine. Infectious disease information may have come from the Centers for Disease Control (CDC). Differential Diagnoses are drawn from clinicians as well as an amalgamation of 3 sources: 1.The Disease Database; 2. Kahan, Scott, Smith, Ellen G. In A Page: Signs and Symptoms. Malden, Massachusetts: Blackwell Publishing, 2004:3; 3. Sailer, Christian, Wasner, Susanne. Differential Diagnosis Pocket. Hermosa Beach, CA: Borm Bruckmeir Publishing LLC, 2002:7 .