Tortuosity

Revision as of 18:41, 30 April 2010 by Elord (talk | contribs) (New page: {{SI}} {{WikiDoc Cardiology Network Infobox}} {{CMG}} thumb|A tortuous river ([[meander of Nowitna River, Alaska)]] '''Tortuosity''' is a property of [...)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

WikiDoc Resources for Tortuosity

Articles

Most recent articles on Tortuosity

Most cited articles on Tortuosity

Review articles on Tortuosity

Articles on Tortuosity in N Eng J Med, Lancet, BMJ

Media

Powerpoint slides on Tortuosity

Images of Tortuosity

Photos of Tortuosity

Podcasts & MP3s on Tortuosity

Videos on Tortuosity

Evidence Based Medicine

Cochrane Collaboration on Tortuosity

Bandolier on Tortuosity

TRIP on Tortuosity

Clinical Trials

Ongoing Trials on Tortuosity at Clinical Trials.gov

Trial results on Tortuosity

Clinical Trials on Tortuosity at Google

Guidelines / Policies / Govt

US National Guidelines Clearinghouse on Tortuosity

NICE Guidance on Tortuosity

NHS PRODIGY Guidance

FDA on Tortuosity

CDC on Tortuosity

Books

Books on Tortuosity

News

Tortuosity in the news

Be alerted to news on Tortuosity

News trends on Tortuosity

Commentary

Blogs on Tortuosity

Definitions

Definitions of Tortuosity

Patient Resources / Community

Patient resources on Tortuosity

Discussion groups on Tortuosity

Patient Handouts on Tortuosity

Directions to Hospitals Treating Tortuosity

Risk calculators and risk factors for Tortuosity

Healthcare Provider Resources

Symptoms of Tortuosity

Causes & Risk Factors for Tortuosity

Diagnostic studies for Tortuosity

Treatment of Tortuosity

Continuing Medical Education (CME)

CME Programs on Tortuosity

International

Tortuosity en Espanol

Tortuosity en Francais

Business

Tortuosity in the Marketplace

Patents on Tortuosity

Experimental / Informatics

List of terms related to Tortuosity

Cardiology Network

Discuss Tortuosity further in the WikiDoc Cardiology Network
Adult Congenital
Biomarkers
Cardiac Rehabilitation
Congestive Heart Failure
CT Angiography
Echocardiography
Electrophysiology
Cardiology General
Genetics
Health Economics
Hypertension
Interventional Cardiology
MRI
Nuclear Cardiology
Peripheral Arterial Disease
Prevention
Public Policy
Pulmonary Embolism
Stable Angina
Valvular Heart Disease
Vascular Medicine

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [11]

File:Nowitna river.jpg
A tortuous river (meander of Nowitna River, Alaska)

Tortuosity is a property of curve being tortuous (twisted; having many turns). There have been several attempts to quantify this property. Tortuosity is commonly used to describe diffusion in porous media [1]. This concept is also used for porous media as soils and snow [2]

Tortuosity in 2-D

Subjective estimation (sometimes aided by optometric grading scales[3]) is often used.

The most simple mathematic method to estimate tortuosity is arc-chord ratio: ratio of the length of the curve (L) to the distance between the ends of it (C):

<math>\tau = \frac{L}{C}</math>

Arc-chord ratio equals 1 for a straight line and is infinite for a circle.

Another method, proposed in 1999[4], is to estimate the tortuosity as integral of square (or module) of curvature. Dividing the result by length of curve or chord has also been tried.

In 2002 several Italian scientists[5] proposed one more method. At first, the curve is divided into several (N) parts with constant sign of curvature (using hysteresis to decrease sensitivity to noise). Then the arc-chord ratio for each part is found and the tortuosity is estimated by:

<math>\tau = \fracTemplate:N - 1{L} \cdot \sum\limits_{i = 1}^N {\left( {\fracTemplate:L iTemplate:S i - 1} \right)}</math>

In this case tortuosity of both straight line and circle is estimated to be 0.

In 1993[6] Swiss mathematician Martin Mächler proposed an analogy: it’s relatively easy to drive a bicycle or a car in a trajectory with a constant curvature (an arc of a circle), but it’s much harder to drive where curvature changes. This would imply that roughness (or tortuosity) could be measured by relative change of curvature. In this case the proposed "local" measure was derivative of logarithm of curvature:

<math>\frac{d}Template:Dx\log \left( \kappa \right) = \fracTemplate:\kappa'{\kappa}</math>

However, in this case tortuosity of a straight line is left undefined.

In 2005 it was proposed to measure tortuosity by an integral of square of derivative of curvature, divided by the length of a curve[7]:

<math>\tau = \frac{{\int\limits_{t_1 }^{t_2 } {\left( {\kappa'\left( t \right)} \right)^2 } dt}}{L}</math>

In this case tortuosity of both straight line and circle is estimated to be 0.

In most of these methods digital filters and approximation by splines can be used to decrease sensitivity to noise.

Tortuosity in 3-D

Usually subjective estimation is used. However, several ways to adapt methods estimating tortuosity in 2-D have also been tried. The methods include arc-chord ratio, arc-chord ratio divided by number of inflection points and integral of square of curvature, divided by length of the curve (curvature is estimated assuming that small segments of curve are planar) [8]. Another method used for quantifying tortuosity in 3D has been applied in 3D reconstructions of solid oxide fuel cell cathodes where the Euclidean distance sums of the centroids of a pore were divided by the length of the pore.[9]

Applications of tortuosity

Tortuosity of blood vessels (for example, retinal and cerebral blood vessels) is known to be used as a medical sign.

In mathematics, cubic splines minimize the functional, equivalent to integral of square of curvature (approximating the curvature as the second derivative).

In many engineering domains dealing with mass transfer in porous materials, such as hydrogeology or heterogeneous catalysis, the tortuosity refers to the ratio of the diffusivity in the free space to the diffusivity in the porous medium[10] (analogous to arc-chord ratio of path). Strictly speaking, however, the effective diffusivity is proportional to the reciprocal of the square of the geometrical tortuosity [11]

In acoustics and following initial works by Maurice Anthony Biot in 1956, the tortuosity is used to describe sound propagation in fluid-saturated porous media. In such media, when frequency of the sound wave is high enough, the effect of viscous drag force between the solid and the fluid can be ignored. In this case, velocity of sound propagation in the fluid in the pores is non-dispersive and compared with the value of the velocity of sound in the free fluid is reduced by a ratio equal to the square root of the tortuosity. This has been used for a number of applications including the study of materials for acoustic isolation, and for oil prospection using acoustics means.

In analytical chemistry applied to polymers and sometimes small molecules tortuosity is applied in Gel permeation chromatography (GPC) also known as Size Exclusion Chromatography (SEC). As with any chromatography it is used to separate mixtures. In the case of GPC the separation is based on molecular size and it works by the use of stationary media with appropriately dimensioned pores. The separation occurs because larger molecules take a shorter, less tortuous path and elute more quickly and smaller molecules can pass into the pores and take a longer, more tortuous path and elute later.

References

  1. Epstein, N. (1989), On tortuosity and the tortuosity factor in flow and diffusion through porous media, Chem. Eng. Sci., 44(3), 777– 779. [1]
  2. Kaempfer, T. U., M. Schneebeli, and S. A. Sokratov (2005), A microstructural approach to model heat transfer in snow, Geophys. Res. Lett., 32, L21503,[2]
  3. Richard M. Pearson. Optometric Grading Scales for use in everyday practice. Optometry Today, Vol. 43, No. 20, 2003, ISSN 0268-5485 [3]
  4. William E. Hart, Michael Goldbaum, Brad Cote, Paul Kube, Mark R. Nelson. Automated measurement of retinal vascular tortuosity. International Journal of Medical Informatics, Vol. 53, No. 2-3, p. 239-252, 1999 [4]
  5. Enrico Grisan, Marco Foracchia, Alfredo Ruggeri. A novel method for automatic evaluation of retinal vessel tortuosity. Proceedings of the 25th Annual International Conference of the IEEE EMBS, Cancun, Mexico, 2003 [5]
  6. M. Mächler, Very smooth nonparametric curve estimation by penalizing change of curvature, Technical Report 71, ETH Zurich, May 1993 [6]
  7. Patasius, M.; Marozas, V.; Lukosevicius, A.; Jegelevicius, D.. Evaluation of tortuosity of eye blood vessels using the integral of square of derivative of curvature // EMBEC'05: proceedings of the 3rd IFMBE European Medical and Biological Engineering Conference, November 20 - 25, 2005, Prague. - ISSN 1727-1983. - Prague. - 2005, Vol. 11, p. [1-4]
  8. E. Bullitt, G. Gerig, S. M. Pizer, Weili Lin, S. R. Aylward. Measuring tortuosity of the intracerebral vasculature from MRA images. IEEE Transactions on Medical Imaging, Volume 22, Issue 9, Sept. 2003, p. 1163 - 1171 [7]
  9. Gostovic, D., et al., Three-dimensional reconstruction of porous LSCF cathodes. Electrochemical and Solid State Letters, 2007. 10(12): p. B214-B217. [8]
  10. Watanabe, Y. and Nakashima, Y. (2001) Two-dimensional random walk program for the calculation of the tortuosity of porous media. Journal of Groundwater Hydrology, 43, 13-22 [9]
  11. Gommes, C.J., Bons, A.-J., Blacher, S. Dunsmuir, J. and Tsou, A. (2009) Practical methods for measuring the tortuosity of porous materials from binary or gray-tone tomographic reconstructions. American Institute of Chemical Engineering Journal, 55, 2000-2012 [10]

de:Tortuosität sv:Tortuositet