Second degree AV block surgery

Jump to navigation Jump to search

Second degree AV block Microchapters

Home

Patient Information

Overview

Historical Perspective

Classification

Pathophysiology

Causes

Differentiating Second degree AV block from other Diseases

Epidemiology and Demographics

Risk Factors

Screening

Natural History, Complications and Prognosis

Diagnosis

Diagnostic Study of Choice

History and Symptoms

Physical Examination

Laboratory Findings

Electrocardiogram

EKG Examples

Chest X Ray

Echocardiography

Other Imaging Findings

Other Diagnostic Studies

Treatment

Medical Therapy

Surgery

Primary Prevention

Secondary Prevention

Cost-Effectiveness of Therapy

Future or Investigational Therapies

Case Studies

Case #1

Second degree AV block surgery On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

slides

Images

American Roentgen Ray Society Images of Second degree AV block surgery

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Second degree AV block surgery

CDC on Second degree AV block surgery

Second degree AV block surgery in the news

Blogs on Second degree AV block surgery

Directions to Hospitals Treating Second degree AV block

Risk calculators and risk factors for Second degree AV block surgery

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor(s)-in-Chief: Cafer Zorkun, M.D., Ph.D. [2]; Raviteja Guddeti, M.B.B.S. [3]

Please help WikiDoc by adding more content here. It's easy! Click here to learn about editing.

Surgery

Mobitz I

Indications for implantation of a pacemaker include:

Dual chamber DDD pacing mode is usually employed in patients with Mobitz I and symptomatic bradycardia. This mode maintains the normal physiologic synchrony between the atria and the ventricles unlike the single chamber VVI mode.

Mobitz II

  • Type II Mobitz (symptomatic or asymptomatic) is by itself an indication for insertion of a pacemaker. Other indications include:
  • Implantation of permanent pacemakers in both asymptomatic and symptomatic patients is usually done. Asymptomatic Mobitz II are prone to be converted to symptomatic or third degree heart block. Thus, they should be considered for a pacemaker even if asymptomatic.
  • A dual chamber DDD pacemaker is preferred over a single chambered VVI pacemakers as it maintains physiologic AV synchrony.
  • A dual-chamber artificial pacemaker is a type of device that typically listens for a pulse from the SA node and sends a pulse to the AV node at an appropriate interval, essentially completing the connection between the two nodes. Pacemakers in this role are usually programmed to enforce a minimum heart rate and to record instances of atrial flutter and atrial fibrillation.