Methods of Pacing

Cardiac pacemakers consist of two parts: a pulse generator or simply generator which is the source of electric pulse, and a variable number of leads that convey the electric signal from the generator to the myocardium. Newer leadless pacemakers have been introduced reducing the risk of complications. There is no formal classification system for the pacemaker. Based upon their duration of use they can be divided into temporary pacing or emergency use pacing and permanent pacing.

Temporary pacing

Temporary pacing is indicated if permanent pacing is not instantly available, not required, or contraindicated. Different types of temporary pacing techniques (based upon the method used to consign the leads to the heart chambers) include transvenous pacing, transcutaneous pacing, epicardial pacing, transesophageal atrial pacing[1], transthoracic mechanical pacing, transthoracic pacing[2] and transmediastinal pacing.


Types of temporary pacing
Type Procedure Use Limitation/ Complication
Transvenous pacing Under sterile conditions, a pacemaker wire guided by fluoroscopy or echocardiography is placed into a vein. Internal jugular vein or subclavian vein are the most common access sites. It is then passed into either the right atrium or right ventricle. The pacing wire is then connected to an external pacemaker outside the body and appropriate mode is selected. Alternative to transcutaneous pacing and bridge to permanent pacing. Infection, thrombosis, pneumothorax, hemothorax, pericardial tamponade[3]
Transcutaneous pacing/ External pacing The procedure described in: External pacing should not be relied upon for an extended period of time. 1.Emergencies as hemodynamically significant bradycardias or asystole
2. bridge to transvenous pacing
discomfort to the patient, risk of burns to skin, musculoskeletal stimulation
Epicardial Pacing Temporary epicardial pacing is used during open-heart surgery should the surgical procedure create atrioventricular block. The electrodes are placed in contact with the outer wall of the ventricle to maintain satisfactory cardiac output until a temporary transvenous electrode has been inserted.
Transesophageal pacing Due to the close proximity to atrium, transesophageal pacing is used.
Transthoracic pacing
Transthoracic mechanical pacing/ Percussive pacing An old procedure involves the use of the closed fist, usually on the left lower edge of the sternum over the right ventricle. According to the British Journal of Anesthesia Striking from a distance of 20 - 30 cm to raise the ventricular pressure 10 - 15mmHg will induce electrical activity and hence ventricular beat.[4] only as a life-saving mean until an electrical pacemaker is available
Transmediastinal pacing


Permanent Pacing

Right atrial and right ventricular leads as visualized under X-ray during a pacemaker implant procedure. The atrial lead is the curved one making a U shape in the upper left part of the figure.

Permanent pacing with an implantable pacemaker involves the transvenous placement of one or more pacing electrodes within a chamber, or chambers, of the heart. The procedure is performed by the incision of a suitable vein into which the electrode lead is inserted and passed along the vein, through the valve of the heart, until positioned in the chamber. The procedure is facilitated by fluoroscopy which enables the physician or cardiologist to view the passage of the electrode lead. After satisfactory lodgment of the electrode is confirmed the opposite end of the electrode lead is connected to the pacemaker generator.

The pacemaker generator is a hermetically sealed device containing a power source, usually a lithium battery, a sensing amplifier which processes the electrical manifestation of naturally occurring heartbeats as sensed by the heart electrodes, the computer logic for the pacemaker and the output circuitry which delivers the pacing impulse to the electrodes.

Most commonly, the generator is placed below the subcutaneous fat of the chest wall, above the muscles and bones of the chest. However, the placement may vary on a case by case basis.

The outer casing of pacemakers is so designed that it will rarely be rejected by the body's immune system. It is usually made of titanium, which is inert in the body.

  1. Verbeet T, Castro J, Decoodt P (October 2003). "Transesophageal pacing: a versatile diagnostic and therapeutic tool". Indian Pacing Electrophysiol J. 3 (4): 202–9. PMC 1502053. PMID 16943920.
  2. Hedges JR, Syverud SA, Dalsey WC (September 1984). "Developments in transcutaneous and transthoracic pacing during bradyasystolic arrest". Ann Emerg Med. 13 (9 Pt 2): 822–7. doi:10.1016/s0196-0644(84)80450-3. PMID 6383140.
  3. Metkus, Thomas S.; Schulman, Steven P.; Marine, Joseph E.; Eid, Shaker M. (2019). "Complications and Outcomes of Temporary Transvenous Pacing". Chest. 155 (4): 749–757. doi:10.1016/j.chest.2018.11.026. ISSN 0012-3692.
  4. (Cite_Journal)Percussion pacing in a three-year-old girl with complete heart block during cardiac catheterization. C Eich, A Bleckmann and T. Paul, retrieved from http://bja.oxfordjournals.org/cgi/content/full/95/4/465