Pacemaker syndrome is a disease that represents the clinical consequences of suboptimal [[Atrioventricular node|atrioventricular]] (AV) synchrony or AV dyssynchrony, regardless of the pacing mode, after the [[Artificial pacemaker#Insertion|pacemaker plantation]].<ref name="pmid9164889">{{cite journal|author=Ellenbogen KA, Gilligan DM, Wood MA, Morillo C, Barold SS |title=The pacemaker syndrome -- a matter of definition |journal=Am. J. Cardiol. |volume=79|issue=9 |pages=1226–9 |year=1997 |month=May |pmid=9164889 |url=http://linkinghub.elsevier.com/retrieve/pii/S0002914997000854|doi=10.1016/S0002-9149(97)00085-4}}</ref><ref name="pmid12555483">{{cite journal |author=Chalvidan T, Deharo JC, Djiane P |title=[Pacemaker syndromes]|language=French |journal=Ann Cardiol Angeiol (Paris) |volume=49 |issue=4 |pages=224–9 |year=2000 |month=July |pmid=12555483 }}</ref>.  It is an [[iatrogenic]]disease that is often underdiagnosed<ref name="pmid9164889">{{cite journal |author=Ellenbogen KA, Gilligan DM, Wood MA, Morillo C, Barold SS |title=The pacemaker syndrome -- a matter of definition |journal=Am. J. Cardiol. |volume=79 |issue=9 |pages=1226–9 |year=1997 |month=May |pmid=9164889|doi=10.1016/S0002-9149(97)00085-4 }}</ref><ref name="isbn0-07-141652-8">{{cite book |author=Baumgartner, William A.; Yuh, David D.; Luca A. Vricella |title=The Johns Hopkins manual of cardiothoracic surgery |publisher=McGraw-Hill Medical Pub |location=New York |year=2007 |origyear= |pages= |quote= |isbn=0-07-141652-8}}</ref>. In general, the symptoms of the [[syndrome]] are a combination of decreased [[cardiac output]], loss of [[atrial]] contribution to[[ventricle|ventricular]] filling, loss of [[total peripheral resistance]] response, and nonphysiologic pressure waves.<ref name="pmid12555483" /><ref name="pmid7821326">{{cite journal |author=Frielingsdorf J, Gerber AE, Hess OM |title=Importance of maintained atrio-ventricular synchrony in patients with pacemakers |journal=Eur. Heart J. |volume=15 |issue=10 |pages=1431–40 |year=1994 |month=October |pmid=7821326|url=http://eurheartj.oxfordjournals.org/cgi/pmidlookup?view=long&pmid=7821326}}</ref><ref name="pmid7511223">{{cite journal |author=Furman S |title=Pacemaker syndrome |journal=Pacing Clin Electrophysiol |volume=17 |issue=1 |pages=1–5 |year=1994 |month=January |pmid=7511223 |doi=10.1111/j.1540-8159.1994.tb01342.x}}</ref>


Individuals with a low heart rate prior to [[pacemaker]] implantation are more at risk of developing pacemaker syndrome. Normally the first chamber of the heart ([[atrium]]) contracts as the second chamber (ventricle) is relaxed, allowing the ventricle to fill before it contracts and pumps blood out of the heart. When the timing between the two chambers goes out of synchronization, less [[blood]] is delivered on each beat. Patients who develop pacemaker syndrome may require adjustment of the pacemaker timing, or another lead fitted to regulate the timing of the chambers separately.
Pacemaker syndrome is a condition that represents the clinical consequences of suboptimal [[Atrioventricular node|atrioventricular]] (AV) synchrony or AV dyssynchrony, regardless of the pacing mode, after [[Artificial pacemaker#Insertion|pacemaker plantation]]. It is an [[iatrogenic ]]disease that is often underdiagnosed.
 
In general, the symptoms of the [[syndrome]] are a combination of decreased [[cardiac output]], loss of [[atrial]] contribution to [[ventricle|ventricular]] filling, loss of [[total peripheral resistance]] response, and nonphysiologic pressure waves.
 
Individuals with a low heart rate prior to [[pacemaker]] implantation are more at risk of developing pacemaker syndrome. Normally the first chamber of the heart ([[atrium]]) contracts as the second chamber ([[ventricle]]) is relaxed, allowing the ventricle to fill before it contracts and pumps blood out of the [[heart]]. When the timing between the two chambers goes out of synchronization, less [[blood]] is delivered on each beat. Patients who develop pacemaker syndrome may require adjustment of the [[pacemaker]] timing, or another lead fitted to regulate the timing of the chambers separately.


==Historical Perspective==
==Historical Perspective==
Since the implantation of [[artificial pacemaker]] in 1958, cases of decreased cardiac output due to ventricular pacing have been reported.  Majority of the patients had increased total peripheral resistance due to aortic and carotid reflexes activity resulting from reduced cardiac output.
 
* Since the implantation of [[artificial pacemaker]] in 1958, cases of decreased cardiac output due to ventricular pacing have been reported.   
 
* Majority of the patients had increased total peripheral resistance due to aortic and carotid reflexes activity resulting from reduced cardiac output.


==Pathophysiology==
==Pathophysiology==
Line 34: Line 40:
==Diagnosis==
==Diagnosis==
===Laboratory Findings===
===Laboratory Findings===
No laboratory tests are usually indicated in pacemaker syndrome.  But levels of [[atrial natriuretic peptide]] and [[brain natriuretic peptide]] can be measured to define the level of cardiac functioning.
 
* No laboratory tests are usually indicated in pacemaker syndrome.  But levels of [[atrial natriuretic peptide]] and [[brain natriuretic peptide]] can be measured to define the level of cardiac functioning.


===Electrocardiogram===
===Electrocardiogram===
Electrocardiographic findings in pacemaker syndrome may include [[prolonged PR interval]], VA conduction due to dyssynchrony between atria and ventricles and/or[[AV dissociation]].
 
* Electrocardiographic findings in pacemaker syndrome may include [[prolonged PR interval]], [[VA conduction]] due to dyssynchrony between atria and ventricles and/or [[AV dissociation]].


==Treatment==
==Treatment==
===Surgery===
===Surgery===
Sometimes surgical intervention is needed. After consulting an electrophysiologist, possibly an additional [[pacemaker]] lead placement is needed, which eventually relieve some of the symptoms.
 
* Sometimes surgical intervention is needed.  
* After consulting an electrophysiologist, an additional [[pacemaker]] lead placement might be needed, which eventually relieves some of the symptoms.


===Prevention===
===Prevention===
At the time of pacemaker implantation, AV synchrony should be optimized to prevent the occurrence of [[pacemaker]] [[syndrome]]. Patients with optimized AV synchrony have shown great results of implantation and very low [[incidence]] of pacemaker syndrome than those with suboptimal AV synchronization.


==References==
* At the time of pacemaker implantation, AV synchrony should be optimized to prevent the occurrence of [[pacemaker]] [[syndrome]].
* Patients with optimized AV synchrony have shown great results and very low [[incidence]] of pacemaker syndrome than those with suboptimal AV synchronization.
* References
{{Reflist|2}}
{{Reflist|2}}
{{WH}}
{{WH}}
Line 55: Line 66:
[[Category:Cardiology]]
[[Category:Cardiology]]
[[Category:Disease]]
[[Category:Disease]]
<references />9. <ref name="pmid11858242">{{cite journal| author=Van Orden Wallace CJ| title=Diagnosing and treating pacemaker syndrome. | journal=Crit Care Nurse | year= 2001 | volume= 21 | issue= 1 | pages= 24-31, 35; quiz 36-7 | pmid=11858242 | doi= | pmc= | url=https://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=11858242  }}</ref>
<references />9.  
<references />

Latest revision as of 03:03, 7 July 2020

Pacemaker syndrome Microchapters

Home

Overview

Historical Perspective

Pathophysiology

Differentiating Pacemaker syndrome from other Diseases

Epidemiology and Demographics

Risk Factors

Natural History, Complications and Prognosis

Diagnosis

History and Symptoms

Physical Examination

Laboratory Findings

Electrocardiogram

Chest X Ray

Echocardiography

Other Imaging Findings

Other Diagnostic Studies

Treatment

Medical Therapy

Surgery

Primary Prevention

Secondary Prevention

Cost-Effectiveness of Therapy

Future or Investigational Therapies

Case Studies

Case #1

Pacemaker syndrome overview On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

slides

Images

American Roentgen Ray Society Images of Pacemaker syndrome overview

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Pacemaker syndrome overview

CDC on Pacemaker syndrome overview

Pacemaker syndrome overview in the news

Blogs on Pacemaker syndrome overview

Directions to Hospitals Treating Pacemaker syndrome

Risk calculators and risk factors for Pacemaker syndrome overview

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor(s)-in-Chief: Raviteja Guddeti, M.B.B.S. [2] Tayebah Chaudhry[3]

Overview

Pacemaker syndrome is a condition that represents the clinical consequences of suboptimal atrioventricular (AV) synchrony or AV dyssynchrony, regardless of the pacing mode, after pacemaker plantation. It is an iatrogenic disease that is often underdiagnosed.

In general, the symptoms of the syndrome are a combination of decreased cardiac output, loss of atrial contribution to ventricular filling, loss of total peripheral resistance response, and nonphysiologic pressure waves.

Individuals with a low heart rate prior to pacemaker implantation are more at risk of developing pacemaker syndrome. Normally the first chamber of the heart (atrium) contracts as the second chamber (ventricle) is relaxed, allowing the ventricle to fill before it contracts and pumps blood out of the heart. When the timing between the two chambers goes out of synchronization, less blood is delivered on each beat. Patients who develop pacemaker syndrome may require adjustment of the pacemaker timing, or another lead fitted to regulate the timing of the chambers separately.

Historical Perspective

  • Since the implantation of artificial pacemaker in 1958, cases of decreased cardiac output due to ventricular pacing have been reported.
  • Majority of the patients had increased total peripheral resistance due to aortic and carotid reflexes activity resulting from reduced cardiac output.

Pathophysiology

  • The loss of physiologic timing of atrial and ventricular contractions, or sometimes called AV dyssynchrony, leads to different mechanisms of symptoms production.
  • Due to loss of AV synchrony, there is no atrial kick, and thus cardiac output decreases.
  • Decrease cardiac effect causes signs and symptoms of Pacemaker syndrome which includes:
    • Shortness of breath
    • Fatigue
    • Chest pain
    • Choking sensation
    • Anxiety
    • Dizziness
    • Confusion
    • Palpitations.
  • This altered ventricular contraction will decrease cardiac output, and in turn will lead to systemic hypotensive reflex response with varying symptoms.[1]

Epidemiology and Demographics

  • The wide range of reported incidence is likely attributable to two factors which are the criteria used to define pacemaker syndrome and the therapy used to resolve that diagnosis.[4]

Diagnosis

Laboratory Findings

Electrocardiogram

Treatment

Surgery

  • Sometimes surgical intervention is needed.
  • After consulting an electrophysiologist, an additional pacemaker lead placement might be needed, which eventually relieves some of the symptoms.

Prevention

  • At the time of pacemaker implantation, AV synchrony should be optimized to prevent the occurrence of pacemaker syndrome.
  • Patients with optimized AV synchrony have shown great results and very low incidence of pacemaker syndrome than those with suboptimal AV synchronization.
  • References
  1. Ellenbogen KA, Gilligan DM, Wood MA, Morillo C, Barold SS (1997). "The pacemaker syndrome—a matter of definition". Am. J. Cardiol. 79 (9): 1226–9. doi:10.1016/S0002-9149(97)00085-4. PMID 9164889. Unknown parameter |month= ignored (help)
  2. Andersen HR, Thuesen L, Bagger JP, Vesterlund T, Thomsen PE (1994). "Prospective randomised trial of atrial versus ventricular pacing in sick-sinus syndrome". Lancet. 344 (8936): 1523–8. doi:10.1016/S0140-6736(94)90347-6. PMID 7983951. Retrieved 2009-06-19. Unknown parameter |month= ignored (help)
  3. Heldman D, Mulvihill D, Nguyen H; et al. (1990). "True incidence of pacemaker syndrome". Pacing and Clinical Electrophysiology : PACE. 13 (12 Pt 2): 1742–50. doi:10.1111/j.1540-8159.1990.tb06883.x. PMID 1704534. Unknown parameter |month= ignored (help); |access-date= requires |url= (help)
  4. Farmer DM, Estes NA, Link MS (2004). "New concepts in pacemaker syndrome". Indian Pacing and Electrophysiology Journal. 4 (4): 195–200. PMC 1502063. PMID 16943933. Retrieved 2009-06-19.

Template:WH Template:WS 9. 9.