ACA 2021 Revascularization Guideline

Class 2a Recommendation, Level of Evidence: B-R[1]
1.Intravascular ultrasound (IVUS) can be used as a procedural guidance in patients undergoing coronary stent implantation, particularly in those with left main or complex coronary artery stenting in order to diminish ischemic events.

2.Optical coherence tomography (OCT is a reasonable alternative to IVUS as an procedural guidance in patients undergoing coronary stent implantation, except in those with ostial left main disease.

Class 2a Recommendation, Level of Evidence: C-LD[1]
If stent failure occurs, both IVUS and OCT can be used to determine the mechanism of stent failure.

Intravenous Ultrasound

Optical Coherence Tomography

References

  1. 1.0 1.1 1.2 1.3 Writing Committee Members. Lawton JS, Tamis-Holland JE, Bangalore S, Bates ER, Beckie TM; et al. (2022). "2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines". J Am Coll Cardiol. 79 (2): e21–e129. doi:10.1016/j.jacc.2021.09.006. PMID 34895950 Check |pmid= value (help).
  2. 2.0 2.1 Maehara A, Matsumura M, Ali ZA, Mintz GS, Stone GW (2017). "IVUS-Guided Versus OCT-Guided Coronary Stent Implantation: A Critical Appraisal". JACC Cardiovasc Imaging. 10 (12): 1487–1503. doi:10.1016/j.jcmg.2017.09.008. PMID 29216976.
  3. 3.0 3.1 Steinberg DH, Mintz GS, Mandinov L, Yu A, Ellis SG, Grube E; et al. (2010). "Long-term impact of routinely detected early and late incomplete stent apposition: an integrated intravascular ultrasound analysis of the TAXUS IV, V, and VI and TAXUS ATLAS workhorse, long lesion, and direct stent studies". JACC Cardiovasc Interv. 3 (5): 486–94. doi:10.1016/j.jcin.2010.03.007. PMID 20488404.
  4. 4.0 4.1 Kobayashi N, Mintz GS, Witzenbichler B, Metzger DC, Rinaldi MJ, Duffy PL; et al. (2016). "Prevalence, Features, and Prognostic Importance of Edge Dissection After Drug-Eluting Stent Implantation: An ADAPT-DES Intravascular Ultrasound Substudy". Circ Cardiovasc Interv. 9 (7): e003553. doi:10.1161/CIRCINTERVENTIONS.115.003553. PMID 27402854.