==Supportive trial data==
==Supportive trial data==


In a study done by Hundley et al. velocity-encoded, phase difference MRI have been found to assess the magnitude of left-to-right shunting as reliably as was done by cardiac catheterization. Also, it has the additional advantage of being a non-invasive tool compared to the invasive cardiac catheterization.<ref name="pmid7796506">{{cite journal| author=Hundley WG, Li HF, Lange RA, Pfeifer DP, Meshack BM, Willard JE et al.| title=Assessment of left-to-right intracardiac shunting by velocity-encoded, phase-difference magnetic resonance imaging. A comparison with oximetric and indicator dilution techniques. | journal=Circulation | year= 1995 | volume= 91 | issue= 12 | pages= 2955-60 | pmid=7796506 | doi= | pmc= | url= }} </ref>
* In a study done by Hundley et al. velocity-encoded, phase difference MRI have been found to assess the magnitude of left-to-right shunting as reliably as was done by cardiac catheterization. Also, it has the additional advantage of being a non-invasive tool compared to the invasive cardiac catheterization.<ref name="pmid7796506">{{cite journal| author=Hundley WG, Li HF, Lange RA, Pfeifer DP, Meshack BM, Willard JE et al.| title=Assessment of left-to-right intracardiac shunting by velocity-encoded, phase-difference magnetic resonance imaging. A comparison with oximetric and indicator dilution techniques. | journal=Circulation | year= 1995 | volume= 91 | issue= 12 | pages= 2955-60 | pmid=7796506 | doi= | pmc= | url= }} </ref>


In another study done by Holmvang et al. Phase-contrast cine MRI has been found to be more reliable than Spin-echo images. The phase contrast MRI defines the defect shape by the cross section of the shunt flow. Due to the accurate diagnosis of the defect size it helps in making a decision on the therapeutics aspect of the patient i.e. transcutaneous catheter or surgical closure. On the other hand, spin-echo images, are not very accurate in finding ASD size and septal thinning adjacent to a secundum ASD may be falsely considered a part of the defect
* In another study done by Holmvang et al. Phase-contrast cine MRI has been found to be more reliable than Spin-echo images. The phase contrast MRI defines the defect shape by the cross section of the shunt flow. Due to the accurate diagnosis of the defect size it helps in making a decision on the therapeutics aspect of the patient i.e. transcutaneous catheter or surgical closure. On the other hand, spin-echo images, are not very accurate in finding ASD size and septal thinning adjacent to a secundum ASD may be falsely considered a part of the defect


==References==
==References==

Revision as of 17:24, 30 August 2011

Atrial Septal Defect Microchapters

Home

Patient Information

Overview

Anatomy

Classification

Ostium Secundum Atrial Septal Defect
Ostium Primum Atrial Septal Defect
Sinus Venosus Atrial Septal Defect
Coronary Sinus
Patent Foramen Ovale
Common or Single Atrium

Pathophysiology

Epidemiology and Demographics

Risk Factors

Natural History and Prognosis

Complications

Diagnosis

History and Symptoms

Physical Examination

Electrocardiogram

Chest X Ray

CT

MRI

Echocardiography

Transesophageal Echocardiography
Transthoracic Echocardiography
Contrast Echocardiography
M-Mode
Doppler

Transcranial Doppler Ultrasound

Cardiac Catheterization

Exercise Testing

ACC/AHA Guidelines for Evaluation of Unoperated Patients

Treatment

Medical Therapy

Surgery

Indications for Surgical Repair
Surgical Closure
Minimally Invasive Repair


Robotic ASD Repair
Percutaneous Closure
Post-Surgical Follow Up

Special Scenarios

Pregnancy
Diving and Decompression Sickness
Paradoxical Emboli
Pulmonary Hypertension
Eisenmenger's Syndrome
Atmospheric Pressure

Case Studies

Case #1

Atrial septal defect MRI On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

Powerpoint slides

Images

American Roentgen Ray Society Images of Atrial septal defect MRI

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Atrial septal defect MRI

CDC on Atrial septal defect MRI

Atrial septal defect MRI in the news

Blogs on Atrial septal defect MRI

Directions to Hospitals Treating Type page name here

Risk calculators and risk factors for Atrial septal defect MRI

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor(s)-In-Chief: Priyamvada Singh, M.B.B.S. [[2]]; Cafer Zorkun, M.D., Ph.D. [3]; Assistant Editor(s)-In-Chief: Kristin Feeney, B.S. [[4]]

Overview

Magneic resonance imaging (MRI) is a noninvasive imaging modality that can be used as a diagnostic tool in identifying an atrial septal defect. MRI aids in direct visualization of the atrial septal defect and pulmonary veins. It can assist in quantifying ventricular volume and function as well as shunt size. Velocity-encoded, phase difference MRI have been found to assess the magnitude of left-to-right shunting as reliably as is done by cardiac catheterization [1]. Also it has the additional advantage of being a non-invasive tool compared to the invasive cardiac catheterization.

Magnest Resonance Imaging (MRI)

  • Non-invasive imaging method
  • Effective tool for when echocardiographic results are inconclusive.
  • Provides better visualization of heart vasculture

Indications

  • Effective in measuring:
  • Flow measurements from the aorta and main pulmonary vein
  • Shunt flow
  • Heart volumes
  • Blood flows
  • Ventricular wall thickness
  • Size of the septum defect
  • Provides identification of additional associated anomalies

Advantages

  • Phase velocity mapping helps in measuring the ratio of pulmonary to systemic blood flow (Qp:Qs).
  • Quantifies ventricular volume and function and shunt size
  • Provides an assessment of the pressure gradient across the valves and atria
  • Can provide morphologic image of the heart in neonates
  • Provides multiple images of the heart per cardiac cycle

Disadvantages

  • Certain physiologic formations can be misidentified, such as a thin fossa ovalis, and mistaken for an ostium secundum defect.
  • Imaging, specifically static images, can provide a skewed perception of the thickness of the septum.
  • Lacks large study backing, needs more clinical trial investigation to further evaluate the potential indications and limitations of the technique.
  • In pediatrics, it may require general anesthesia. This may be less desirable as echocardiography does not.

Supportive trial data

  • In a study done by Hundley et al. velocity-encoded, phase difference MRI have been found to assess the magnitude of left-to-right shunting as reliably as was done by cardiac catheterization. Also, it has the additional advantage of being a non-invasive tool compared to the invasive cardiac catheterization.[1]
  • In another study done by Holmvang et al. Phase-contrast cine MRI has been found to be more reliable than Spin-echo images. The phase contrast MRI defines the defect shape by the cross section of the shunt flow. Due to the accurate diagnosis of the defect size it helps in making a decision on the therapeutics aspect of the patient i.e. transcutaneous catheter or surgical closure. On the other hand, spin-echo images, are not very accurate in finding ASD size and septal thinning adjacent to a secundum ASD may be falsely considered a part of the defect

References

  1. 1.0 1.1 Hundley WG, Li HF, Lange RA, Pfeifer DP, Meshack BM, Willard JE; et al. (1995). "Assessment of left-to-right intracardiac shunting by velocity-encoded, phase-difference magnetic resonance imaging. A comparison with oximetric and indicator dilution techniques". Circulation. 91 (12): 2955–60. PMID 7796506.

Template:WH Template:WS