Cardiac resynchronization therapy complications

Jump to navigation Jump to search

Cardiac resynchronization therapy Microchapters

Home

Overview

Indications

Landmark Trials

Contraindications

Pathophysiologic Basis for CRT

Treatment

Preoperative Evaluation

Procedure

Recovery

Outcomes and Prognosis

Complications

Cardiac resynchronization therapy complications On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

Powerpoint slides

Images

American Roentgen Ray Society Images of Cardiac resynchronization therapy complications

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Cardiac resynchronization therapy complications

CDC on Cardiac resynchronization therapy complications

Cardiac resynchronization therapy complications in the news

Blogs on Cardiac resynchronization therapy complications

Directions to Hospitals Administering Cardiac resynchronization therapy

Risk calculators and risk factors for Cardiac resynchronization therapy complications

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor(s)-In-Chief:: Bhaskar Purushottam, M.D. [2] Synonyms and Keywords: CRT

Overview

Complications

The performance of the CRT procedure itself can be associated with several complications including: #Bleeding

  1. Infection
  2. Pneumothorax (0.9% in CRT trials, Medicare registry[1] reported 1.2%),
  3. Lead dislodgement
  4. Myocardial injury
  5. Coronary sinus dissection (1.3%) or perforation (1.3%)(complication rate related to coronary veins has been reported in 2%)
  6. Pericardial tamponade.

Pocket erosion, hematomas (2.4%; in routine clinical practice, the actual incidence of pocket hematomas is probably higher as the trials only reported those hematomas, which needed surgical intervention), lead fracture, lead dislodgements (CRT trials demonstrated a rate verying from 2.9% to 10.6%; the MIRACLE-ICD[2] study demonstrated a higher occurence of lead dislodgement with left ventricular lead than right atrial and right ventricular leads-6.8%, 15 and 0.6% respectively) and device infection are common post procedural complications. It is important to note that early re-intervention of pocket hematomas is associated with a 15-fold increase in infection[3]. Given the proximity of the posterior wall of the left ventricle to the phrenic nerve, there remains the risk of inappropriate phrenic nerve stimulation. For CRT patients, the average in-hospital mortality is 0.3% and the 30 day mortality is 0.7%. Reynolds et al.[1] showed a 1.1% in-hospital mortality in 30,984 Medicare patients undergoing CRT. This disparity in the in-hospital mortality rates can be explained by the strict inclusion criteria of the trials, where the patients are more healthier than the patients in real life practice.[4]

References

  1. 1.0 1.1 Reynolds MR, Cohen DJ, Kugelmass AD, Brown PP, Becker ER, Culler SD; et al. (2006). "The frequency and incremental cost of major complications among medicare beneficiaries receiving implantable cardioverter-defibrillators". J Am Coll Cardiol. 47 (12): 2493–7. doi:10.1016/j.jacc.2006.02.049. PMC 1800827. PMID 16781379.
  2. Young JB, Abraham WT, Smith AL, Leon AR, Lieberman R, Wilkoff B; et al. (2003). "Combined cardiac resynchronization and implantable cardioversion defibrillation in advanced chronic heart failure: the MIRACLE ICD Trial". JAMA. 289 (20): 2685–94. doi:10.1001/jama.289.20.2685. PMID 12771115.
  3. Klug D, Balde M, Pavin D, Hidden-Lucet F, Clementy J, Sadoul N; et al. (2007). "Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators: results of a large prospective study". Circulation. 116 (12): 1349–55. doi:10.1161/CIRCULATIONAHA.106.678664. PMID 17724263.
  4. van Rees JB, de Bie MK, Thijssen J, Borleffs CJ, Schalij MJ, van Erven L (2011). "Implantation-related complications of implantable cardioverter-defibrillators and cardiac resynchronization therapy devices a systematic review of randomized clinical trials". J Am Coll Cardiol. 58 (10): 995–1000. doi:10.1016/j.jacc.2011.06.007. PMID 21867832.

Template:WH Template:WS