Platelet function analyzer: Difference between revisions

Jump to navigation Jump to search
(New page: {{SI}} '''Associate Editors-in-Chief:''' Davide Capodanno, M.D. [mailto:Davide.Capodanno@jax.ufl.edu] {{EJ}} ==Overview== Normal 0 false false false EN-...)
 
No edit summary
 
Line 6: Line 6:


==Overview==
==Overview==
    Normal  0                  false  false  false      EN-US  X-NONE  X-NONE
The Platelet Function Analyzer-100(PFA-100, Siemens Healthcare Diagnostics, Inc., Deerfield, IL) is a test based on the principle of shear-induced [[aggregation]]. Although it is not a COX-1specific [[assay]], it allows monitoring of [[aspirin]] effects by providing a quantitative measure of platelet-related [[hemostasis]] in anticoagulated whole [[blood]].  
The Platelet Function Analyzer-100(PFA-100, Siemens Healthcare Diagnostics, Inc., Deerfield, IL) is a test based on the principle of shear-induced [[aggregation]]. Although it is not a COX-1specific [[assay]], it allows monitoring of [[aspirin]] effects by providing a quantitative measure of platelet-related [[hemostasis]] in anticoagulated whole [[blood]].  



Latest revision as of 11:47, 9 June 2009

WikiDoc Resources for Platelet function analyzer

Articles

Most recent articles on Platelet function analyzer

Most cited articles on Platelet function analyzer

Review articles on Platelet function analyzer

Articles on Platelet function analyzer in N Eng J Med, Lancet, BMJ

Media

Powerpoint slides on Platelet function analyzer

Images of Platelet function analyzer

Photos of Platelet function analyzer

Podcasts & MP3s on Platelet function analyzer

Videos on Platelet function analyzer

Evidence Based Medicine

Cochrane Collaboration on Platelet function analyzer

Bandolier on Platelet function analyzer

TRIP on Platelet function analyzer

Clinical Trials

Ongoing Trials on Platelet function analyzer at Clinical Trials.gov

Trial results on Platelet function analyzer

Clinical Trials on Platelet function analyzer at Google

Guidelines / Policies / Govt

US National Guidelines Clearinghouse on Platelet function analyzer

NICE Guidance on Platelet function analyzer

NHS PRODIGY Guidance

FDA on Platelet function analyzer

CDC on Platelet function analyzer

Books

Books on Platelet function analyzer

News

Platelet function analyzer in the news

Be alerted to news on Platelet function analyzer

News trends on Platelet function analyzer

Commentary

Blogs on Platelet function analyzer

Definitions

Definitions of Platelet function analyzer

Patient Resources / Community

Patient resources on Platelet function analyzer

Discussion groups on Platelet function analyzer

Patient Handouts on Platelet function analyzer

Directions to Hospitals Treating Platelet function analyzer

Risk calculators and risk factors for Platelet function analyzer

Healthcare Provider Resources

Symptoms of Platelet function analyzer

Causes & Risk Factors for Platelet function analyzer

Diagnostic studies for Platelet function analyzer

Treatment of Platelet function analyzer

Continuing Medical Education (CME)

CME Programs on Platelet function analyzer

International

Platelet function analyzer en Espanol

Platelet function analyzer en Francais

Business

Platelet function analyzer in the Marketplace

Patents on Platelet function analyzer

Experimental / Informatics

List of terms related to Platelet function analyzer

Associate Editors-in-Chief: Davide Capodanno, M.D. [1]

Please Join in Editing This Page and Apply to be an Editor-In-Chief for this topic: There can be one or more than one Editor-In-Chief. You may also apply to be an Associate Editor-In-Chief of one of the subtopics below. Please mail us [2] to indicate your interest in serving either as an Editor-In-Chief of the entire topic or as an Associate Editor-In-Chief for a subtopic. Please be sure to attach your CV and or biographical sketch.

Overview

The Platelet Function Analyzer-100(PFA-100, Siemens Healthcare Diagnostics, Inc., Deerfield, IL) is a test based on the principle of shear-induced aggregation. Although it is not a COX-1specific assay, it allows monitoring of aspirin effects by providing a quantitative measure of platelet-related hemostasis in anticoagulated whole blood.

The system comprises a microprocessor-controlled tool and a disposable test cartridge containing a biologically active nitrocellulose membrane. To perform the test, 0.8 ml of citrated whole blood is transferred into the reservoir of the cartridge within 4 h of blood sampling. After warming the anticoagulated blood to 37 °C, the instrument aspirates a blood sample under vacuum from the reservoir through a 200 μm diameter stainless steel capillary and a 150 μm aperture cut into the membrane, which is coated with collagen and epinephrine (CEPI) or collagen and ADP (CADP).

The presence of these biochemical stimuli, and the high shear rates of 5000–6000 s−1 generated under the standardized flow conditions, result in platelet aggregate forms that block the aperture of the membrane. The time required to obtain full occlusion of the aperture is reported as the closure time (CT).

Prolonged CT with only the CEPI cartridge is observed with mild inherited platelet function disorders and with aspirin ingestion, while prolonged CTs with both CEPI and CADP cartridges are associated with more severe inherited platelet dysfunctions. An advantage of the PFA-100 application as a platelet function assay is that it is a rapid, accurate, simple, and reproducible test that requires only a small volume of blood. It cannot be considered as a point of care as minimal pipetting is required to use this test. One of its major disadvantages is that it is poorly sensitive in detecting effects of thienopyridines and therefore should not be used for this purpose. Newer generation assays are currently under development to assess thienopyridine effects.

Template:SIB Template:WH Template:WS