You don't need to be Editor-In-Chief to add or edit content to WikiDoc. You can begin to add to or edit text on this WikiDoc page by clicking on the edit button at the top of this page. Next enter or edit the information that you would like to appear here. Once you are done editing, scroll down and click the Save page button at the bottom of the page.

Jump to: navigation, search

The sievert (symbol: Sv) is the SI derived unit of dose equivalent. It attempts to reflect the biological effects of radiation as opposed to the physical aspects, which are characterised by the absorbed dose, measured in grays. It is named after Rolf Sievert, a Swedish medical physicist famous for work on radiation dosage measurement and research into the biological effects of radiation.

Definition

The equivalent dose to a tissue is found by multiplying the absorbed dose, in grays, by a dimensionless "quality factor" Q, dependent upon radiation type, and by another dimensionless factor N, dependent on all other pertinent factors. N depends upon the part of the body irradiated, the time and volume over which the dose was spread, even the species of the subject. Together, Q and N constitute the radiation weighting factor, WR . For an organism composed of multiple tissue types a weighted sum or integral is often used. (In 2002, the CIPM decided that the distinction between Q and N causes too much confusion and therefore deleted the factor N from the definition of absorbed dose in the SI brochure. [1].)

In terms of SI base units:

1 Sv = 1 J/kg = 1 m2/s2 = 1 m2·s–2

Although the sievert has the same dimensions as the gray (i.e. joules per kilogram), it measures a different thing. To avoid any risk of confusion between the absorbed dose and the equivalent dose, the corresponding special units, namely the gray instead of the joule per kilogram for absorbed dose and the sievert instead of the joule per kilogram for the dose equivalent, should be used. For a given amount of radiation (measured in grays), the biological effect (measured in sieverts) can vary considerably as a result of the radiation weighting factor WR.

SI multiples and conversions

Frequently used SI multiples are the millisievert (1 mSv = 10–3 Sv) and microsievert (1 μSv = 10–6 Sv).

An older unit of the equivalent dose is the rem (Roentgen equivalent man); 1 Sv is equal to 100 rem. In some fields and countries, rem and mrem continue to be used along with Sv and mSv, unavoidably causing confusion (1 Sv = 100 rem, 10 mSv = 1 rem: it is hard to memorize when to use which conversion factor).

Explanation

Various terms are used with this unit:

  • Dose equivalent
  • Ambient dose equivalent
  • Directional dose equivalent
  • Personal dose equivalent
  • Organ equivalent dose

The millisievert (mSv) is commonly used to measure the effective dose in diagnostic medical procedures (e.g. X-rays, nuclear medicine, positron emission tomography and computed tomography). The natural background effective dose varies considerably from place to place, but typically is around 2.4 mSv/year [2] (pdf).

For acute full body equivalent dose, 1 Sv causes slight blood changes, 2-5 Sv causes nausea, hair loss, hemorrhage and will cause death in many cases. More than 3 Sv will lead to death in 50% of cases within 30 days, and over 6 Sv survival is unlikely. See radiation poisoning for a more complete analysis of effects of various dosage levels.

Given the linear no-threshold model of radiation response , the collective dose that a population is exposed to is measured in "man-sieverts" (man.Sv).

Q values

Here are some quality factor values:

  • Photons, all energies : Q = 1
  • Electrons and muons, all energies : Q = 1
  • Neutrons,
    • energy < 10 keV : Q = 5
    • 10 keV < energy < 100 keV : Q = 10
    • 100 keV < energy < 2 MeV : Q = 20
    • 2 MeV < energy < 20 MeV : Q = 10
    • energy > 20 MeV : Q = 5
  • Protons, energy > 2 MeV : Q = 5
  • Alpha particles and other atomic nuclei : Q = 20

N values

Here are some N values for organs and tissues:

And for other organisms, relative to humans:

Template:SI unit lowercase

See also


References

cs:Sievert

de:Sievert (Einheit) et:Siivertfa:سیورت fr:Sievert ko:시버트 it:Sievert he:זיוורט mk:Сиверт nl:Sievert ja:シーベルト (単位) no:Sievert nn:Sievertsr:Сиверт fi:Sievert sv:Sievert uk:Зіверт

WikiDoc Help Menu

Quick Start..

Editing basics

Advanced editing

Communicating your edits

Help Videos You Can Watch


Acknowledgement and Attribution Regarding Sources of Content

Some of the initial content on this page may be incorporated in part from copyleft sources in the public domain including wikis such as Wikipedia and AskDrWiki. Drug information for patients came from the The National Library of Medicine. Infectious disease information may have come from the Centers for Disease Control (CDC). Differential Diagnoses are drawn from clinicians as well as an amalgamation of 3 sources: 1.The Disease Database; 2. Kahan, Scott, Smith, Ellen G. In A Page: Signs and Symptoms. Malden, Massachusetts: Blackwell Publishing, 2004:3; 3. Sailer, Christian, Wasner, Susanne. Differential Diagnosis Pocket. Hermosa Beach, CA: Borm Bruckmeir Publishing LLC, 2002:7 .

Personal tools